Matlab Evaluate Acoustic Metrics

MathWorksOfficialCreated by MathWorks

  • Skill
  • Tool integration
  • Science and research
  • BSD-2-Clause
  • No issues found

From the author

Select and use Audio Toolbox acoustic, psychoacoustic, and speech quality metrics. Use when computing loudness, sharpness, roughness, fluctuation strength, noise criteria (NC/RNC/RC), speech transmission index (STI), speech intelligibility index (SII), speech quality (ViSQOL, STOI), SPL, reverberation time (RT60), tone-to-noise ratio, or prominence ratio. Also use when asked about PESQ, POLQA, calibration factor, EBU R 128, LUFS, HVAC noise, background noise evaluation, or how to measure audio quality or noise compliance. Covers calibration, standard selection, signal alignment, and the complete function inventory including what does NOT exist.
— the description by MathWorks

AutoGineer summary

Written by AutoGineer from the skill’s own files, not by the author

This skill provides a structured approach to using MATLAB Audio Toolbox for acoustic measurement and analysis. It guides users through selecting the correct functions for psychoacoustic metrics, speech intelligibility, noise compliance, and broadcast loudness. The skill emphasizes proper calibration techniques, standard-compliant workflows, and the correct handling of signal data to ensure accurate results, while explicitly warning against the use of nonexistent or licensed-restricted functions.

What it does

  • Calculates psychoacoustic metrics like loudness, sharpness, roughness, and fluctuation strength.
  • Evaluates speech quality and intelligibility using metrics such as ViSQOL, STOI, STI, and SII.
  • Assesses noise compliance using NC, RC, and RNC ratings for various environments.
  • Performs offline SPL measurements and broadcast loudness checks (EBU R 128).
  • Provides guidance on microphone calibration and system-level calibration factors.
  • Offers standard-compliant filtering and unit conversion utilities.

When to use it

  • When you need to measure perceived loudness or sound quality in a research or engineering context.
  • When evaluating room acoustics or HVAC noise compliance against industry standards.
  • When analyzing speech intelligibility for communication systems or public address setups.
  • When you need to calibrate audio recordings for accurate SPL or metric computation.
  • When you need to perform broadcast loudness compliance checks.

Advantages

  • Ensures adherence to international standards like ISO 532-1/2, ANSI/ASA S12.2, and IEC 60268-16.
  • Prevents common errors such as incorrect function usage, argument ordering, or manual implementation of complex algorithms.
  • Provides clear guidance on calibration to ensure measurement accuracy.
  • Streamlines the selection of appropriate metrics based on specific application goals.

Usage examples

“How do I calculate the loudness of a recording in sones?”
The agent will guide you to use the acousticLoudness function, specifying the ISO 532-1 method, applying your calibration factor, and selecting the appropriate sound field.
“Is my office HVAC noise compliant?”
The agent will recommend using the roomCriteria function to obtain an RC rating, explaining how to interpret the output and verify the measurement conditions.
“How can I measure the speech quality of a processed audio file?”
The agent will instruct you to use the visqol function with the 'speech' mode, ensuring the processed signal is passed as the first argument.
“How do I calibrate my microphone for SPL measurements?”
The agent will explain how to use calibrateMicrophone with a 1 kHz tone recording and a known SPL reference to compute the correct calibration factor.

Install

  1. Download the skill as a ZIP:

    https://autogineer.com/agent-skills/matlab/matlab-evaluate-acoustic-metrics/download
  2. Unzip it into the cross-client skills folder of your project:

    mkdir -p .agents/skills && unzip matlab-evaluate-acoustic-metrics.zip -d .agents/skills

Documentation by MathWorks

Evaluate Acoustic Metrics

Select the correct Audio Toolbox function for acoustic measurement, apply proper calibration, and choose appropriate standards — instead of reimplementing algorithms or calling nonexistent functions.

When to Use

  • Computing psychoacoustic metrics (loudness, sharpness, roughness, fluctuation)

  • Evaluating speech quality or intelligibility (ViSQOL, STOI, STI, SII)

  • Assessing noise compliance (NC rating, RC rating, RNC, SIL)

  • Measuring SPL from recordings (offline, calibrated)

  • Computing broadcast loudness (EBU R 128 / LUFS)

  • Measuring reverberation time (RT60) from impulse responses

  • Detecting tonal content (tone-to-noise ratio, prominence ratio)

  • Converting microphone sensitivity to CalibrationFactor

  • User mentions PESQ or POLQA (redirect to correct alternatives)

When NOT to Use

  • Real-time streaming audio processing loops — use matlab-process-streaming-audio

  • Audio device I/O, recording, or live calibrateMicrophone — use matlab-play-record-audio

  • Audio plugin authoring (VST/AU) — use matlab-write-audio-plugin

  • General filter design unrelated to measurement — use matlab-design-digital-filter

  • Spatial audio / HRTF / SOFA processing

Workflow

Follow this decision tree to route the user's goal to the right function:

1. Identify the measurement goal
GoalCategoryGo to
"How loud is it?" (perceived)Psychoacoustic→ Psychoacoustic Metrics
"Does it comply with broadcast loudness?"Broadcast→ Broadcast Loudness
"Is the noise level acceptable for this space?"Noise compliance→ Noise Compliance
"Can people understand speech in this room?"Speech intelligibility→ STI/SII Measurement
"How good does processed speech sound?"Speech quality→ Speech Quality
"What's the SPL?"Level measurement→ SPL Measurement
"What's the reverberation time?"Room acoustics→ RT60
"Is there a tonal component?"Tonality→ Tonality
2. Ask before computing

Before writing code, confirm these with the user:

  • Calibration: Do they have a CalibrationFactor? Did they calibrate with calibrateMicrophone? (See Calibration section)

  • Standard: Which standard or method applies? (ISO 532-1 vs 532-2, NC vs RC vs RNC)

  • Sound field: Free field or diffuse field recording?

  • Application context: What space type? What's the concern? (Drives NC vs RC vs RNC selection)

3. Select function and apply

Use the Key Functions table and the category-specific patterns below.

Functions That Do NOT Exist

FunctionStatusUse Instead
pesqDoes NOT exist (proprietary ITU-T P.862 license)visqol(degraded, reference, fs, Mode="speech")
polqaDoes NOT exist (proprietary ITU-T P.863 license)visqol(degraded, reference, fs)

Never suggest pesq or polqa. They are not in Audio Toolbox and cannot be added due to licensing.

Key Functions

FunctionPurposeStandardAvailable From
acousticLoudnessPerceived loudness (sones)ISO 532-1/2R2020a
acousticSharpnessPerceived sharpness (acum)DIN 45692R2020a
acousticRoughnessPerceived roughness (asper)—R2021a
acousticFluctuationFluctuation strength (vacil)—R2020b
integratedLoudnessBroadcast loudness (LUFS)EBU R 128 / ITU-R BS.1770R2016b
loudnessMeterStreaming broadcast loudness meterEBU R 128 / ITU-R BS.1770R2018a
visqolFull-reference audio quality (MOS)—R2024a
stoiShort-time objective intelligibility—R2024a
mnruModulated noise reference unitITU-T P.810R2024a
dBovPower level relative to overload (dB)ITU-T G.100.1R2024a
speechTransmissionIndexSTI from IR or test signalsIEC 60268-16R2026a
speechIntelligibilityIndexSII from IR, test signals, or levelsANSI/ASA S3.5-1997R2026b
stipaExcitationGenerate STI/STIPA test signalsIEC 60268-16R2026a
siiExcitationGenerate SII test signalsANSI/ASA S3.5-1997R2026b
noiseCriteriaNC rating + SIL + spectrum imbalance + rattle riskANSI/ASA S12.2R2026b
roomNoiseCriteriaRNC rating (detects surging/fluctuations)ANSI/ASA S12.2R2026b
roomCriteriaRC Mark II rating (HVAC systems)ANSI/ASA S12.2R2026b
noiseCriteriaCurvesLook up NC curve valuesANSI/ASA S12.2R2026b
noiseCriteriaRecommendationsRecommended NC levels by room typeANSI/ASA S12.2R2026b
speechInterferenceLevelSIL from recordingANSI/ASA S12.2R2026b
rt60Reverberation time from impulse responseISO 3382-1/2R2025a
acousticToneToNoiseRatioDetect/quantify tonesECMA-418-1R2023b
acousticProminenceRatioTonality via critical band comparisonECMA-418-1R2023b
splMeterSPL measurement (time-weighted, per-band)IEC 61672R2018a
calibrateMicrophoneCompute calibration factor from known tone—R2018b
weightingFilterA/C/Z/K frequency weightingIEC 61672-1R2016b
octaveFilterSingle octave-band filterANSI S1.11-2004R2017b
octaveFilterBankMulti-band octave filteringANSI S1.11-2004R2019a

See references/function-arguments.md for complete argument lists, defaults, and valid values for each function — consult when constructing calls with non-default parameters.

Calibration

CalibrationFactor from microphone sensitivity

Convert dB sensitivity (dBV/Pa) to the linear CalibrationFactor:

sensitivity_dBV = -26;  % Example: -26 dBV/Pa microphone
calibrationFactor = 1 / 10^(sensitivity_dBV/20);

The CalibrationFactor is the 3rd positional argument for acousticLoudness, acousticSharpness, acousticRoughness, and acousticFluctuation (default: sqrt(8)). For noise compliance functions, pass it as a name-value: CalibrationFactor=value.

System-level calibration advice

Always ask the user about their signal chain. If the recording path includes a preamp, audio interface, or ADC with unknown gain, the mic sensitivity spec alone is insufficient. Recommend:

  1. Play a 1 kHz tone through the system and record it through the full signal chain (mic → preamp → ADC → WAV). Use a pistonphone for a known 94 dB reference, or place a physical SPL meter next to the microphone to get an SPL reading.

  2. Compute the system calibration factor: calibrationFactor = calibrateMicrophone(calRecording, fs, SPLreading, FrequencyWeighting="Z-weighting")

  3. Pass that factor to the measurement function

calibrateMicrophone expects a 1 kHz tone recording as input. The SPLreading argument is the known SPL in dB (e.g., 94 from a pistonphone, or the value shown on a physical SPL meter).

Cross-reference: for the physical recording workflow with calibrateMicrophone, see the matlab-play-record-audio skill.

Patterns

Psychoacoustic Metrics
[audioIn, fs] = audioread("recording.wav");
calFactor = 1 / 10^(-26/20);

loudness = acousticLoudness(audioIn, fs, calFactor, ...
    Method="ISO 532-1", SoundField="diffuse", TimeVarying=true);

sharpness = acousticSharpness(audioIn, fs, calFactor, ...
    SoundField="diffuse", TimeVarying=true);

roughness = acousticRoughness(audioIn, fs, calFactor, SoundField="diffuse");

fluctuation = acousticFluctuation(audioIn, fs, calFactor, SoundField="diffuse");

Return types: acousticLoudness returns a scalar (sones) for stationary analysis. With TimeVarying=true, it returns a column vector (time-varying loudness in sones). The second output (specificLoudness) is a matrix (time x critical bands). It does NOT return a struct or timetable.

Ask the user:

  • ISO 532-1 (Zwicker, stationary/time-varying) or ISO 532-2 (Moore-Glasberg)?

  • Free-field or diffuse-field recording?

  • Time-varying analysis needed?

See references/psychoacoustic-metrics.md for method selection guidance (ISO 532-1 vs 532-2), interpretation tables (sone values, sharpness/roughness/fluctuation scales), tonality metric selection, and combined sound quality assessment workflows.

Unit Conversions

Use built-in functions — do NOT reimplement conversion formulas manually:

ConversionFunctionMethod selection
phon → sonephon2sone(phon, standard)"ISO 532-1" (default), "ISO 532-2"
sone → phonsone2phon(sone, standard)"ISO 532-1" (default), "ISO 532-2"
Hz → ERBhz2erb(freq)Single formula (no variants)
ERB → Hzerb2hz(erb)Single formula (no variants)
Hz → barkhz2bark(freq)Single formula (no variants)
bark → Hzbark2hz(bark)Single formula (no variants)
Hz → melhz2mel(freq, MelStyle=s)"oshaughnessy" (default), "slaney"
mel → Hzmel2hz(mel, MelStyle=s)"oshaughnessy" (default), "slaney"

When the user specifies a standard (e.g., "ISO 532-2"), pass it as the second positional argument for phon2sone/sone2phon. For hz2mel/mel2hz, use the MelStyle name-value pair.

Noise Compliance

Choose the function based on the application:

SituationFunctionWhy
General background noise ratingnoiseCriteriaStandard NC curves (ANSI/ASA S12.2)
HVAC system noise specificallyroomCriteriaRC Mark II designed for HVAC evaluation
Noise with audible surging/fluctuationroomNoiseCriteriaRNC penalizes time-varying noise (requires ≥15 s recording)
Quick speech interference checkspeechInterferenceLevelDirect SIL value
Need recommended levels for room typenoiseCriteriaRecommendationsLookup table by room use
[audioIn, fs] = audioread("office_noise.wav");

[NC, SIL, specImbalance, rattleRisk] = noiseCriteria(audioIn, fs, ...
    CalibrationFactor=2.3);

[RC, LMF, QAI, rattleRisk] = roomCriteria(audioIn, fs, ...
    CalibrationFactor=2.3);

SIL = speechInterferenceLevel(audioIn, fs, CalibrationFactor=2.3);

rec = noiseCriteriaRecommendations("NC", Occupancy="all");

Return types:

  • NC is a string (e.g., "NC-35" or "NC-56 (1000 Hz)" if a band exceeds)

  • RC is a string (e.g., "RC-32(N)" — the letter indicates spectrum quality: N/R/H/RV)

  • SIL and LMF are double scalars (dB)

  • QAI is a double scalar (dB; 0 = ideal neutral)

  • specImbalance and rattleRisk are structs with .Summary (string) and .Details (table) — access .Summary for display. Exception: specImbalance degrades to a char scalar (not a struct) when NC exceeds the curve range (e.g., "Above NC-70") or falls below NC-15. Guard with isstruct(specImbalance) before dot-indexing.

  • noiseCriteriaRecommendations requires a criteria name argument: "NC", "RNC", or "RC"

Ask the user:

  • What type of space? (office, classroom, hospital, concert hall)

  • Is the noise source HVAC? → prefer roomCriteria

  • Is the noise steady or fluctuating? → if fluctuating, use roomNoiseCriteria

See references/noise-compliance.md for detailed output interpretation and selection guidance.

Speech Quality
[degraded, fs] = audioread("processed_speech.wav");
[reference, ~] = audioread("reference_speech.wav");

mosScore = visqol(degraded, reference, fs, Mode="speech");

intelligibility = stoi(degraded, reference, fs);

Critical: stoi and visqol argument order is (processed, reference, fs) — processed/degraded signal FIRST.

visqol modes: "speech" for narrowband/wideband speech (outputs 1-5 MOS), "audio" (default) for general audio.

STI/SII Measurement

Two methods are available for both speechTransmissionIndex and speechIntelligibilityIndex:

IR-based method (simpler — no alignment needed):

[ir, fs] = audioread("room_impulse_response.wav");
sti = speechTransmissionIndex(ir, fs);
sii = speechIntelligibilityIndex(ir, fs);

Direct method (from test signals transmitted through the system):

fs = 48000;
reference = stipaExcitation(fs, Duration=15);
% Transmit reference through system, record as 'processed'
[processed, ~] = audioread("received_stipa.wav");

% IMPORTANT: Align signals before computing (see Signal Alignment)
processed = alignsignals(processed, reference);

sti = speechTransmissionIndex(processed, reference, fs);

Ask the user:

  • Do they have an impulse response? → use IR method (simpler, no alignment needed)

  • Measuring live? → generate test signal, transmit, record, align, compute

  • STI or SII? STI for room/PA systems (IEC 60268-16); SII for hearing/communication (ANSI S3.5)

See references/sti-measurement.md for STI NV arguments, post-processing adjustment workflow (Annex M), test signal generation, and result interpretation. See references/sii-measurement.md for SII standard clause selection (5.1-5.3), BandImportanceFunction guidance, measurement positioning, and result interpretation.

SPL Measurement (Offline)
[audioIn, fs] = audioread("recording.wav");

spl = splMeter(SampleRate=fs, ...
    Bandwidth="Full band", ...
    FrequencyWeighting="A-weighting", ...
    TimeWeighting="fast", ...
    CalibrationFactor=2.3);

[Lt, Leq, Lpeak, Lmax] = spl(audioIn);

% For a single overall value, read the final row
fprintf("Leq: %.1f dB(A)\n", Leq(end));

Valid Bandwidth values: "Full band" (overall level), "1 octave", "2/3 octave", "1/3 octave". There is no "broadband" option — use "Full band" for a single overall SPL value.

Output arity: All outputs (Lt, Leq, Lpeak, Lmax) have one row per input sample. For a 12-second file at 44.1 kHz, that is 539,648 rows. Never fprintf or disp the full output — it will hang. Instead:

  • Single overall value: read Leq(end) (the final accumulated value)

  • Time-interval readings: downsample to interval boundaries: Leq(round(fs*T):round(fs*T):end, :) where T is the desired interval in seconds

TimeInterval controls the integration window for Leq computation but does NOT reduce the number of output rows.

Do not manually compute 20*log10(rms(audioIn)/20e-6) — splMeter handles calibration, weighting, and time integration correctly per IEC 61672.

Multi-band (octave-band) SPL: Use splMeter with Bandwidth="1 octave" — do NOT use octaveFilterBank + manual dB conversion. Key properties for octave-band SPL:

[audioIn, fs] = audioread("recording.wav");

spl = splMeter(SampleRate=fs, ...
    Bandwidth="1 octave", ...
    FrequencyWeighting="Z-weighting", ...
    TimeWeighting="fast", ...
    FrequencyRange=[15 8000], ...
    OctaveFilterOrder=8, ...
    CalibrationFactor=2.3);

[Lt, Leq, Lpeak, Lmax] = spl(audioIn);
cf = getCenterFrequencies(spl);

Critical gotchas for octave-band splMeter:

  • Property name is OctaveFilterOrder (not FilterOrder). FilterOrder does not exist on splMeter.

  • FrequencyRange compares against true center frequencies (fc = 1000 × 10^(3b/10) per IEC 61260), not nominal values. A band is included only if its true center falls within [lower, upper]. Bands below 1 kHz have true centers slightly above nominal (e.g., "63 Hz" = 63.10); bands above 1 kHz have true centers below nominal (e.g., "2 kHz" = 1995.26, "8 kHz" = 7943.28). Use floor(true_center) for lower bounds and ceil(true_center) for upper bounds. Common case "16 Hz to 8 kHz": use [15 8000] — the 16 Hz true center is 15.85 (so 15 ≤ 15.85 includes it) and 8 kHz true center is 7943 (so 8000 ≥ 7943 includes it). Do NOT use [16 8000] — this drops the 16 Hz band.

  • Output is per-sample (see Output arity note above). Never print the full output. For time-interval readings, downsample: Lt100ms = Lt(round(fs*0.1):round(fs*0.1):end, :);

See references/spl-measurement.md for weighting selection guidance (A/C/Z and fast/slow), SPL interpretation tables, occupational exposure limits, splMeter vs poctave equivalency, and common measurement scenarios.

Broadcast Loudness (EBU R 128)
[audioIn, fs] = audioread("broadcast_content.wav");
[loudness, loudnessRange] = integratedLoudness(audioIn, fs);

% Check compliance: target is -23 LUFS +/- 1 LU
isCompliant = abs(loudness - (-23)) <= 1;

Use integratedLoudness for offline compliance checks. Use loudnessMeter for streaming/real-time monitoring (see matlab-process-streaming-audio).

RT60
[ir, fs] = audioread("room_ir.wav");
rtsummary = rt60(ir, fs, Bandwidth="1 octave");

Ask the user:

  • What is the room type? (drives the target RT60)

  • Do they have an IR, or do they need to measure one?

  • T30 (standard) vs T20 (when noise floor limits dynamic range)?

See references/rt60-measurement.md for target RT60 values by space type, T20/T30/EDT interpretation, frequency-dependent analysis, and relationship to STI.

Tonality
[audioIn, fs] = audioread("machine_noise.wav");

[tnr, tnrFreq, isProminent] = acousticToneToNoiseRatio(audioIn, fs);

[pr, prFreq, isProminent] = acousticProminenceRatio(audioIn, fs);

All outputs are empty (0×1) when no tonal components are detected. Check isempty(tnr) before indexing.

Standards-Compliant Filters (Custom Preprocessing)

The metric functions above perform standards-compliant filtering internally. Use standalone filter objects only for custom measurement workflows where no single metric function applies AND you do not need SPL output:

% A-weighting filter
wf = weightingFilter("A-weighting", fs);
weightedSignal = wf(audioIn);

% Octave-band filter bank (for waveform-level band decomposition only)
ofb = octaveFilterBank("1 octave", fs, ...
    FrequencyRange=[31.5 16000], FilterOrder=8);
bandSignals = ofb(audioIn);

If you need octave-band SPL levels, use splMeter with Bandwidth="1 octave" instead of octaveFilterBank + manual dB conversion. See the Multi-band SPL section above.

Signal Alignment

FunctionInternal alignment?Action
visqolYesNo action needed
stoiNoAlign before calling
speechTransmissionIndexNoAlign for direct method; IR method avoids issue
speechIntelligibilityIndexNoAlign for direct method; IR method avoids issue

For the direct (processed, reference, fs) method, always align signals:

processed = alignsignals(processed, reference);

SII is more sensitive to misalignment than STI. At 50 ms delay: SII error ~0.016, STI negligible. At 200 ms: SII ~0.036, STI ~0.017. The IR-based (ir, fs) method avoids alignment issues entirely.

Common Mistakes

MistakeWhy it failsCorrect approach
Call pesq(reference, degraded, fs)Function does not existvisqol(degraded, reference, fs, Mode="speech")
stoi(reference, processed, fs)Wrong argument orderstoi(processed, reference, fs) — processed FIRST
acousticFluctuationStrength(...)Wrong function nameacousticFluctuation(audioIn, fs, calFactor)
Implement NC from scratch with hardcoded curvesMisses SIL, spectrum imbalance, rattle risknoiseCriteria(audioIn, fs, CalibrationFactor=cf)
20*log10(rms(x)/20e-6) for SPLNo weighting, no time integration, no calibrationsplMeter with appropriate settings
Implement STI algorithm manually~100 lines, error-prone, misses NV optionsspeechTransmissionIndex(ir, fs)
Divide signal by calibration factor manuallyIncorrect; factor is a multiplier, not a divisorPass as positional arg or CalibrationFactor=value
Skip alignment for direct STI/SIISilent accuracy degradationalignsignals(processed, reference) before calling
Use acousticLoudness for broadcast loudnessWrong standard (ISO 532 = sones, not LUFS)integratedLoudness for EBU R 128 compliance
string(rattleRisk) or fprintf("%s", specImbalance)These are structs, not stringsAccess .Summary field: rattleRisk.Summary
specImbalance.Summary when NC is out of curve rangespecImbalance degrades to char (not struct) when "Above NC-70" or below NC-15Guard: if isstruct(specImbalance), disp(specImbalance.Summary); end
roomNoiseCriteria on recordings shorter than 15 sANSI/ASA S12.2-2019 requires ≥150 Lt samples at 100 ms intervalsEnsure recording is at least 15 seconds; use noiseCriteria for shorter clips
round(NC) or arithmetic on NC/RC outputNC and RC are strings, not numbersUse directly: fprintf("%s\n", NC)
noiseCriteriaRecommendations() with no argsFirst argument (criteria name) is requirednoiseCriteriaRecommendations("NC")
loudness.OverallLoudness after acousticLoudnessReturns a scalar or vector, not a structUse directly: fprintf("%.1f sones\n", loudness)
splMeter(..., FilterOrder=8)Property does not exist on splMeterUse OctaveFilterOrder=8
splMeter(..., FrequencyRange=[16 8000]) for 16 Hz–8 kHzDrops 16 Hz band (true center is 15.85 Hz, which is below 16)Use FrequencyRange=[15 8000] — use floor(true_center) for lower bound
octaveFilterBank + 20*log10(rms(band)/pRef) for SPLManual, no time weighting, no calibration integrationUse splMeter with Bandwidth="1 octave"
Treating splMeter output as a single valueAll outputs have one row per input sample (e.g., 539k rows for 12s at 44.1 kHz)Use Leq(end) for a single value, or downsample to interval boundaries

Conventions

  • Always ask about the user's measurement goal before selecting a function

  • Always ask about calibration — recommend calibrateMicrophone for system-level accuracy

  • Default to SoundField="free" for anechoic/outdoor, "diffuse" for reverberant rooms

  • Default to Method="ISO 532-1" for loudness (Zwicker method, most common)

  • Use IR-based methods for STI/SII when an impulse response is available (avoids alignment)

  • Pass CalibrationFactor explicitly rather than pre-scaling the signal

  • For noise compliance, prefer roomCriteria for HVAC and noiseCriteria for general background noise


Copyright 2026 The MathWorks, Inc.


Files

references/sii-measurement.md

SII Measurement

Intake Questions

1. What is the application?

SII measures whether speech is audible and intelligible under given noise and hearing conditions. Common use cases:

ApplicationTypical Approach
Room/system evaluation with a recordingIR-based or Direct method (like STI)
Hearing aid evaluationLevel-only method with InsertionGain and HearingThresholdLevel
Telecom or communication system designDirect method through the system
Noise environment assessment (no audio)Level-only method with estimated noise and speech levels
Classroom design for hearing-impaired studentsLevel-only method with HearingThresholdLevel and room noise
2. Do they have audio, or just level specifications?
  • Have IR or audio: Use IR-based or Direct method (same as STI)

  • Only have noise levels and speech specs: Use the Level-only method -- no audio signal needed. Provide noise level, vocal effort, and distance.

3. Listener characteristics

Ask about:

  • Hearing loss: Does the listener have elevated hearing thresholds? -> HearingThresholdLevel (dB HL per band)

  • Conductive hearing loss: -> ConductiveHearingLossLevel (must be <= HearingThresholdLevel)

  • Hearing device: Is an amplification device being evaluated? -> InsertionGain (gain curve per band)

  • Binaural advantage: Is the listener using both ears? -> IsBinaural=true (adds ~1 dB effective SNR benefit)

4. Communication conditions (Level-only method)
  • Vocal effort: Normal, raised, loud, or shout? (Changes spectral shape, not just level)

  • Distance: Talker-to-listener distance in meters (inverse-square-law attenuation applied)

  • Noise level: Measured or estimated background noise (scalar dB OASPL or per-band vector)

  • Measurement location: Free-field or at eardrum? (Affects the transfer function applied)

5. Band procedure

SII can use different frequency resolution:

  • "critical band" -- 21 bands (default for IR/Direct methods)

  • "1/3 octave band" -- 18 bands

  • "equally-contributing critical band" -- 17 bands

  • "octave band" -- 6 bands (least precise, fastest)

The choice affects precision slightly; "1/3 octave band" is common for practical measurements.

Standard Clauses & Workflow Selection

The ANSI/ASA S3.5-1997 standard defines three calculation methods (clauses 5.1-5.3) in increasing order of generality. The standard also allows workflows outside these clauses.

When to Use Each Clause
ClauseConditions RequiredTypical Scenario
5.1 (Levels only)Low reverberation; listener faces source directly (or omnidirectional); speech and noise are independent; system is linearOffice noise assessment, outdoor environments, simple room predictions
5.2 (Measurements at listener position)Well-mixed sound field OR direct facing/omnidirectional; linear system; identical conditions in both earsRoom acoustics with measurement mic at head center, PA system evaluation
5.3 (Measurements at eardrum)Linear system; identical conditions in both ears; measurements taken at eardrum (HATS or probe mic)Hearing device evaluation, eardrum-level assessment, binaural research
Practical Scenario Mapping
ScenarioRecommended ApproachRationale
"Will speech be intelligible in this room design?" (no measurements)Clause 5.1 -- level-only method with estimated noise and standard speechFastest; no equipment needed; sufficient for design-stage predictions
"Evaluate speech intelligibility of installed PA system"Clause 5.2 -- IR or direct method with mic at listener head positionCaptures room acoustics and system response; standard positioning
"Assess hearing aid benefit for a patient"Clause 5.3 -- with InsertionGain, HearingThresholdLevel, eardrum measurement locationModels device insertion gain and listener-specific hearing loss
"Compare noise environments for regulatory compliance"Clause 5.1 -- with measured noise levels per bandStandard-compliant with measured noise; speech levels from standard
"Evaluate classroom acoustics with measured IR"Clause 5.2 -- IR method with measured ambient noiseRealistic room assessment; compare to ANSI S12.60 targets
"Assess telecom system speech quality"Clause 5.2 -- direct method with siiExcitation through the codecCaptures codec distortion and frequency shaping
Measurement Positioning by Clause

Clause 5.1 (free-field, no audio):

  • No physical microphone measurement required for the SII computation itself

  • If measuring noise levels: place mic at center of listener's head position, without listener present

  • Speech levels typically come from the standard (selected via VocalEffort) or custom measurements at 1 m from talker

Clause 5.2 (free-field, at listener position):

  • Microphone at center of listener's head, mid-point between ears

  • Listener must NOT be present during measurement

  • Transmit excitation signal from the talker/source position

  • Set SpeechMeasurementLocation="free-field" and NoiseMeasurementLocation="free-field"

Clause 5.3 (eardrum):

  • Use a Head and Torso Simulator (HATS) designed for eardrum measurements, OR

  • Probe tube microphone within 5 mm of eardrum on >=8 otologically normal subjects (age 18-30)

  • Set SpeechMeasurementLocation="eardrum" and NoiseMeasurementLocation="eardrum"

  • Must specify SpeechAndNoiseLevel when using IR or direct method with eardrum location

Workflows Beyond the Standard

The three standard clauses do not cover every valid use case. Common non-standard workflows:

WorkflowApproachKey Differences from Standard Clauses
Hearing device evaluation (no room measurement)Level-only method + InsertionGain + HearingThresholdLevelUses clause 5.1 inputs but adds device/listener parameters
Binaural advantage assessmentAny clause + IsBinaural=trueReduces equivalent hearing threshold by 1.7 dB
Custom speech material weightingAny clause + custom BandImportanceFunction vectorWeights bands differently than standard speech
Noise environment comparison (parametric)Level-only method, vary NoiseLevelQuick what-if analysis without re-measuring
In-ear monitor evaluationDirect method + eardrum location + InsertionGainCombines clause 5.3 positioning with device modeling
Classroom design for hearing-impairedLevel-only method + HearingThresholdLevel + room noiseClause 5.1 with listener-specific hearing model
BandImportanceFunction Selection

The BIF weights frequency bands by their relative importance to intelligibility. Choice depends on the speech material being evaluated:

BIF ValueSpeech MaterialWhen to Use
"standard"Average English sentencesDefault for most assessments -- general-purpose
"NNS"Nonsense syllables (CVC)When testing pure audibility without linguistic context
"CID-22"CID Everyday SentencesClinical audiometry with sentence-level material
"NU6"Northwestern University Auditory Test No. 6Monosyllabic word recognition testing
"DRT"Diagnostic Rhyme TestMilitary/tactical communication systems assessment
"Short Passages"Connected discourse (paragraphs)Lecture/presentation intelligibility; high redundancy
"SPIN"Speech Perception in Noise sentencesAssessment in noisy environments; high-context and low-context
Custom vectorUser-definedSpecialized material, non-English languages, music intelligibility

Guidance:

  • Use "standard" unless the assessment targets a specific test protocol

  • For hearing aid fitting/evaluation, match the BIF to the clinical test material used

  • For communication system certification, match the BIF to the test protocol (e.g., DRT for military standards)

  • Custom vectors must have one value per band (B values) and contain at least one nonzero element -- the function normalizes so they sum to 1

SpeechAndNoiseLevel for Standard Compliance

For IR-based and direct methods, the standard recommends specifying SpeechAndNoiseLevel. This corresponds to the Combined Speech and Noise Spectrum Level (CSNSL) in ANSI/ASA S3.5-1997 clauses 5.2/5.3 -- the unmodulated spectrum level of the received signal (speech + noise together) measured at the listener position or eardrum.

  • Measure with a calibrated SPL meter at the listener position during normal operational conditions (speech + noise simultaneously present)

  • Report as a per-band vector in dB SPL for standard compliance (scalar OASPL is accepted but may be non-compliant)

  • If you cannot measure combined levels, specify NoiseLevel separately (the function derives E' and N' differently)

When using the IR method with separately measured noise: The IR captures the room's effect on speech but does not contain ambient noise. If background noise is present during operation, specify NoiseLevel as a per-band vector measured at the listener position with the speech source off. The function adds this noise contribution to the SII calculation. Without it, the function assumes negligible noise (-50 dB/Hz per band).

speechIntelligibilityIndex

Three syntaxes are available. NV arguments are syntax-specific -- using the wrong argument for a syntax causes an error.

Method 1: IR-based
[ir, fs] = audioread("room_ir.wav");
sii = speechIntelligibilityIndex(ir, fs);
Method 2: Direct (test signal)
fs = 48000;
[reference, speechRef] = siiExcitation(fs, Duration=16);

% --- Transmit 'reference' through system, record 'processed' ---

% Align signals (required -- SII is more sensitive to misalignment than STI)
% alignsignals requires vector input; use finddelay on one column instead
delay = finddelay(reference(:,1), processed(:,1));
if delay > 0
    processed = processed(delay+1:end, :);
    reference = reference(1:size(processed,1), :);
elseif delay < 0
    reference = reference(-delay+1:end, :);
    processed = processed(1:size(reference,1), :);
end

sii = speechIntelligibilityIndex(processed, reference, fs);
Method 3: From levels only (no audio signal)

SII can be computed from speech and noise level specifications alone:

sii = speechIntelligibilityIndex();

sii = speechIntelligibilityIndex(Method="1/3 octave band", ...
    NoiseLevel=40, VocalEffort="raised", Distance=2);
Name-Value Arguments by Syntax

Valid for IR-based and Direct methods only:

ArgumentDefaultPurpose
SpeechAndNoiseLevel--Combined speech+noise level per band (dB SPL vector). Recommended for standard compliance.
NoiseLevel-50 dB/Hz per bandNoise level -- numeric vector (dB SPL) or scalar (dB OASPL)

Note: For standard-compliant SII results with the IR or Direct method, specify SpeechAndNoiseLevel as a per-band vector. Without it, the function uses default levels and emits a warning.

Valid for Level-only method only:

ArgumentDefaultPurpose
SpeechLevel"standard""standard", "idealized", or numeric vector (dB SPL)
NoiseLevel-50 dB/Hz per bandNoise level -- numeric vector (dB SPL) or scalar (dB OASPL)
Distance1 mTalker-to-listener distance
VocalEffort"normal""normal", "raised", "loud", "shout"

Valid for all syntaxes:

ArgumentDefaultPurpose
Method--Band procedure: "critical band", "1/3 octave band", "equally-contributing critical band", "octave band"
InsertionGain0 dBHearing device gain (scalar or 1-by-B vector)
HearingThresholdLevel0 dB HLListener hearing threshold (scalar or 1-by-B vector)
ConductiveHearingLossLevel0 dB HLConductive hearing loss (must be <= HearingThresholdLevel)
BandImportanceFunction"standard""standard", "NNS", "CID-22", "NU6", "DRT", "Short Passages", "SPIN"
SpeechMeasurementLocation"free-field""free-field" or "eardrum"
NoiseMeasurementLocation"free-field""free-field" or "eardrum"
IsBinauralfalseBinaural listening advantage

Critical constraints:

  • VocalEffort, Distance, and SpeechLevel are INVALID for IR-based and Direct methods -- they cause an error

  • SpeechAndNoiseLevel is INVALID for the Level-only method -- use SpeechLevel and NoiseLevel separately instead

  • ConductiveHearingLossLevel must be <= HearingThresholdLevel in all bands

Ask the user about:

  • What is the talker-to-listener distance? (level-only method)

  • What vocal effort level? (level-only method)

  • Does the listener have hearing loss? (affects HearingThresholdLevel)

  • Is a hearing device being evaluated? (InsertionGain)

  • What noise level is present? (measured or estimated)

Outputs
[sii, baf, mtf] = speechIntelligibilityIndex(ir, fs, ...
    NoiseLevel=40);
  • sii -- Speech intelligibility index (0 to 1)

  • baf -- Band audibility function (table)

  • mtf -- Modulation transfer function (table)

siiExcitation

[mtfExcitation, speechExcitation, expLevels] = siiExcitation(fs, Duration=16);

mtfExcitation = siiExcitation(fs, Duration=20, ...
    VocalEffort="raised", Method="1/3 octave band");

The expLevels output provides expected speech spectrum levels for system calibration.

Signal Alignment

speechIntelligibilityIndex does not perform internal alignment for the direct method. SII is more sensitive to misalignment than STI.

Impact of misalignment (empirically measured):

DelaySII Error (20s signal)
<=50 ms0.016 (significant)
100 ms0.029
200 ms0.036

Always align for the direct method. Because siiExcitation returns an N-by-9 matrix (not a vector), use finddelay on one column:

delay = finddelay(reference(:,1), processed(:,1));
if delay > 0
    processed = processed(delay+1:end, :);
    reference = reference(1:size(processed,1), :);
elseif delay < 0
    reference = reference(-delay+1:end, :);
    processed = processed(1:size(reference,1), :);
end

The IR-based method avoids this issue entirely -- impzest deconvolution handles propagation delay during IR extraction.

Complete Workflow: Evaluate SII for Hearing Device

sii = speechIntelligibilityIndex( ...
    Method="1/3 octave band", ...
    NoiseLevel=50, ...
    VocalEffort="normal", ...
    Distance=1, ...
    InsertionGain=gainCurve, ...
    HearingThresholdLevel=audiogram);

Interpreting Results

SII Scale
SII RangeInterpretation
0.75-1.00Speech highly intelligible; nearly all speech cues audible
0.45-0.75Moderate intelligibility; context helps significantly
0.20-0.45Poor intelligibility; only familiar phrases understood
< 0.20Speech essentially inaudible above the noise
Key Differences from STI
  • SII measures audibility of speech given noise and hearing -- can the listener detect speech cues?

  • STI measures transmission fidelity -- does the channel preserve modulations?

  • SII can be computed without any audio (level-only method) -- just noise spectrum + speech level + hearing threshold

  • SII accounts for listener hearing loss; STI does not

  • SII is more appropriate for hearing device evaluation; STI is more appropriate for room/PA evaluation

Band Audibility Function (BAF) Diagnostics

The BAF output shows the proportion of speech information audible in each frequency band (0 = completely masked, 1 = fully audible):

  • Low BAF at low frequencies: Low-frequency noise masks speech fundamentals -- less critical for intelligibility

  • Low BAF at 1-4 kHz: Critical concern -- these bands carry the most speech information (consonant cues)

  • Low BAF at high frequencies with normal hearing: HF noise or air absorption

  • Low BAF at high frequencies with hearing loss: Expected sensorineural pattern -- evaluate hearing device InsertionGain in these bands

Troubleshooting

ObservationLikely CauseAction
Error about invalid NV argumentWrong argument for the syntax -- VocalEffort/Distance only valid for Level-only methodCheck which syntax is being used; see constraints table above
SII = 1.0 (perfect)Speech far above noise in all bandsExpected for close-range, quiet conditions with normal hearing
SII near 0 with moderate noiseHearingThresholdLevel too high, or noise level wrongVerify units -- noise should be dB SPL, hearing in dB HL
SII doesn't change with InsertionGainGain doesn't overcome the hearing threshold deficitCheck that InsertionGain + SpeechLevel - NoiseLevel > HearingThresholdLevel in critical bands
Warning about default levelsSpeechAndNoiseLevel not specified for IR/Direct methodProvide measured per-band levels for standard-compliant results

Copyright 2026 The MathWorks, Inc.


Requirements and compatibility

Works with: Claude Code, Claude apps, OpenAI Codex, GitHub Copilot, Cursor, Gemini CLI, Kiro, OpenCode, Goose, Amp, Roo Code, JetBrains Junie, Factory Droid, Devin (ex-Windsurf), Mistral Vibe, OpenHands, Letta

“Works with” means the tool reads the open Agent Skills format; a skill written for one tool may use features others lack.

Security

No issues found by our static scan· No issues found

A static scan is not a guarantee. Skills are third-party content: review a skill before you let an agent use it.

Attribution and licence

Created by
MathWorks
Publisher
MathWorks (Official)
Source
matlab/matlab-agentic-toolkit · skills-catalog/signal-processing/matlab-evaluate-acoustic-metrics · commit 2a7f215
Licence
BSD 2-Clause License (redistribution allowed)
  • LICENSE (added by AutoGineer from LICENSE.md)
  • ATTRIBUTION.md (written by AutoGineer)
Synced

AutoGineer is not affiliated with or endorsed by MathWorks or MathWorks.

Download ZIP

The ZIP holds the skill’s files, its licence files and an ATTRIBUTION.md. Download matlab-evaluate-acoustic-metrics.zip