Matlab Evaluate Acoustic Metrics
MathWorksOfficialCreated by MathWorks
- Skill
- Tool integration
- Science and research
- BSD-2-Clause
- No issues found
AutoGineer summary
Written by AutoGineer from the skill’s own files, not by the author
This skill provides a structured approach to using MATLAB Audio Toolbox for acoustic measurement and analysis. It guides users through selecting the correct functions for psychoacoustic metrics, speech intelligibility, noise compliance, and broadcast loudness. The skill emphasizes proper calibration techniques, standard-compliant workflows, and the correct handling of signal data to ensure accurate results, while explicitly warning against the use of nonexistent or licensed-restricted functions.
What it does
- Calculates psychoacoustic metrics like loudness, sharpness, roughness, and fluctuation strength.
- Evaluates speech quality and intelligibility using metrics such as ViSQOL, STOI, STI, and SII.
- Assesses noise compliance using NC, RC, and RNC ratings for various environments.
- Performs offline SPL measurements and broadcast loudness checks (EBU R 128).
- Provides guidance on microphone calibration and system-level calibration factors.
- Offers standard-compliant filtering and unit conversion utilities.
When to use it
- When you need to measure perceived loudness or sound quality in a research or engineering context.
- When evaluating room acoustics or HVAC noise compliance against industry standards.
- When analyzing speech intelligibility for communication systems or public address setups.
- When you need to calibrate audio recordings for accurate SPL or metric computation.
- When you need to perform broadcast loudness compliance checks.
Advantages
- Ensures adherence to international standards like ISO 532-1/2, ANSI/ASA S12.2, and IEC 60268-16.
- Prevents common errors such as incorrect function usage, argument ordering, or manual implementation of complex algorithms.
- Provides clear guidance on calibration to ensure measurement accuracy.
- Streamlines the selection of appropriate metrics based on specific application goals.
Usage examples
- “How do I calculate the loudness of a recording in sones?”
- The agent will guide you to use the acousticLoudness function, specifying the ISO 532-1 method, applying your calibration factor, and selecting the appropriate sound field.
- “Is my office HVAC noise compliant?”
- The agent will recommend using the roomCriteria function to obtain an RC rating, explaining how to interpret the output and verify the measurement conditions.
- “How can I measure the speech quality of a processed audio file?”
- The agent will instruct you to use the visqol function with the 'speech' mode, ensuring the processed signal is passed as the first argument.
- “How do I calibrate my microphone for SPL measurements?”
- The agent will explain how to use calibrateMicrophone with a 1 kHz tone recording and a known SPL reference to compute the correct calibration factor.
Install
Download the skill as a ZIP:
https://autogineer.com/agent-skills/matlab/matlab-evaluate-acoustic-metrics/downloadUnzip it into the cross-client skills folder of your project:
mkdir -p .agents/skills && unzip matlab-evaluate-acoustic-metrics.zip -d .agents/skills
Documentation by MathWorks
Evaluate Acoustic Metrics
Select the correct Audio Toolbox function for acoustic measurement, apply proper calibration, and choose appropriate standards — instead of reimplementing algorithms or calling nonexistent functions.
When to Use
Computing psychoacoustic metrics (loudness, sharpness, roughness, fluctuation)
Evaluating speech quality or intelligibility (ViSQOL, STOI, STI, SII)
Assessing noise compliance (NC rating, RC rating, RNC, SIL)
Measuring SPL from recordings (offline, calibrated)
Computing broadcast loudness (EBU R 128 / LUFS)
Measuring reverberation time (RT60) from impulse responses
Detecting tonal content (tone-to-noise ratio, prominence ratio)
Converting microphone sensitivity to CalibrationFactor
User mentions PESQ or POLQA (redirect to correct alternatives)
When NOT to Use
Real-time streaming audio processing loops — use
matlab-process-streaming-audioAudio device I/O, recording, or live
calibrateMicrophone— usematlab-play-record-audioAudio plugin authoring (VST/AU) — use
matlab-write-audio-pluginGeneral filter design unrelated to measurement — use
matlab-design-digital-filterSpatial audio / HRTF / SOFA processing
Workflow
Follow this decision tree to route the user's goal to the right function:
1. Identify the measurement goal
| Goal | Category | Go to |
|---|---|---|
| "How loud is it?" (perceived) | Psychoacoustic | → Psychoacoustic Metrics |
| "Does it comply with broadcast loudness?" | Broadcast | → Broadcast Loudness |
| "Is the noise level acceptable for this space?" | Noise compliance | → Noise Compliance |
| "Can people understand speech in this room?" | Speech intelligibility | → STI/SII Measurement |
| "How good does processed speech sound?" | Speech quality | → Speech Quality |
| "What's the SPL?" | Level measurement | → SPL Measurement |
| "What's the reverberation time?" | Room acoustics | → RT60 |
| "Is there a tonal component?" | Tonality | → Tonality |
2. Ask before computing
Before writing code, confirm these with the user:
Calibration: Do they have a CalibrationFactor? Did they calibrate with
calibrateMicrophone? (See Calibration section)Standard: Which standard or method applies? (ISO 532-1 vs 532-2, NC vs RC vs RNC)
Sound field: Free field or diffuse field recording?
Application context: What space type? What's the concern? (Drives NC vs RC vs RNC selection)
3. Select function and apply
Use the Key Functions table and the category-specific patterns below.
Functions That Do NOT Exist
| Function | Status | Use Instead |
|---|---|---|
pesq | Does NOT exist (proprietary ITU-T P.862 license) | visqol(degraded, reference, fs, Mode="speech") |
polqa | Does NOT exist (proprietary ITU-T P.863 license) | visqol(degraded, reference, fs) |
Never suggest pesq or polqa. They are not in Audio Toolbox and cannot be added due to licensing.
Key Functions
| Function | Purpose | Standard | Available From |
|---|---|---|---|
acousticLoudness | Perceived loudness (sones) | ISO 532-1/2 | R2020a |
acousticSharpness | Perceived sharpness (acum) | DIN 45692 | R2020a |
acousticRoughness | Perceived roughness (asper) | — | R2021a |
acousticFluctuation | Fluctuation strength (vacil) | — | R2020b |
integratedLoudness | Broadcast loudness (LUFS) | EBU R 128 / ITU-R BS.1770 | R2016b |
loudnessMeter | Streaming broadcast loudness meter | EBU R 128 / ITU-R BS.1770 | R2018a |
visqol | Full-reference audio quality (MOS) | — | R2024a |
stoi | Short-time objective intelligibility | — | R2024a |
mnru | Modulated noise reference unit | ITU-T P.810 | R2024a |
dBov | Power level relative to overload (dB) | ITU-T G.100.1 | R2024a |
speechTransmissionIndex | STI from IR or test signals | IEC 60268-16 | R2026a |
speechIntelligibilityIndex | SII from IR, test signals, or levels | ANSI/ASA S3.5-1997 | R2026b |
stipaExcitation | Generate STI/STIPA test signals | IEC 60268-16 | R2026a |
siiExcitation | Generate SII test signals | ANSI/ASA S3.5-1997 | R2026b |
noiseCriteria | NC rating + SIL + spectrum imbalance + rattle risk | ANSI/ASA S12.2 | R2026b |
roomNoiseCriteria | RNC rating (detects surging/fluctuations) | ANSI/ASA S12.2 | R2026b |
roomCriteria | RC Mark II rating (HVAC systems) | ANSI/ASA S12.2 | R2026b |
noiseCriteriaCurves | Look up NC curve values | ANSI/ASA S12.2 | R2026b |
noiseCriteriaRecommendations | Recommended NC levels by room type | ANSI/ASA S12.2 | R2026b |
speechInterferenceLevel | SIL from recording | ANSI/ASA S12.2 | R2026b |
rt60 | Reverberation time from impulse response | ISO 3382-1/2 | R2025a |
acousticToneToNoiseRatio | Detect/quantify tones | ECMA-418-1 | R2023b |
acousticProminenceRatio | Tonality via critical band comparison | ECMA-418-1 | R2023b |
splMeter | SPL measurement (time-weighted, per-band) | IEC 61672 | R2018a |
calibrateMicrophone | Compute calibration factor from known tone | — | R2018b |
weightingFilter | A/C/Z/K frequency weighting | IEC 61672-1 | R2016b |
octaveFilter | Single octave-band filter | ANSI S1.11-2004 | R2017b |
octaveFilterBank | Multi-band octave filtering | ANSI S1.11-2004 | R2019a |
See references/function-arguments.md for complete argument lists, defaults, and valid values for each function — consult when constructing calls with non-default parameters.
Calibration
CalibrationFactor from microphone sensitivity
Convert dB sensitivity (dBV/Pa) to the linear CalibrationFactor:
sensitivity_dBV = -26; % Example: -26 dBV/Pa microphone
calibrationFactor = 1 / 10^(sensitivity_dBV/20);The CalibrationFactor is the 3rd positional argument for acousticLoudness, acousticSharpness, acousticRoughness, and acousticFluctuation (default: sqrt(8)). For noise compliance functions, pass it as a name-value: CalibrationFactor=value.
System-level calibration advice
Always ask the user about their signal chain. If the recording path includes a preamp, audio interface, or ADC with unknown gain, the mic sensitivity spec alone is insufficient. Recommend:
Play a 1 kHz tone through the system and record it through the full signal chain (mic → preamp → ADC → WAV). Use a pistonphone for a known 94 dB reference, or place a physical SPL meter next to the microphone to get an SPL reading.
Compute the system calibration factor:
calibrationFactor = calibrateMicrophone(calRecording, fs, SPLreading, FrequencyWeighting="Z-weighting")Pass that factor to the measurement function
calibrateMicrophone expects a 1 kHz tone recording as input. The SPLreading argument is the known SPL in dB (e.g., 94 from a pistonphone, or the value shown on a physical SPL meter).
Cross-reference: for the physical recording workflow with calibrateMicrophone, see the matlab-play-record-audio skill.
Patterns
Psychoacoustic Metrics
[audioIn, fs] = audioread("recording.wav");
calFactor = 1 / 10^(-26/20);
loudness = acousticLoudness(audioIn, fs, calFactor, ...
Method="ISO 532-1", SoundField="diffuse", TimeVarying=true);
sharpness = acousticSharpness(audioIn, fs, calFactor, ...
SoundField="diffuse", TimeVarying=true);
roughness = acousticRoughness(audioIn, fs, calFactor, SoundField="diffuse");
fluctuation = acousticFluctuation(audioIn, fs, calFactor, SoundField="diffuse");Return types: acousticLoudness returns a scalar (sones) for stationary analysis. With TimeVarying=true, it returns a column vector (time-varying loudness in sones). The second output (specificLoudness) is a matrix (time x critical bands). It does NOT return a struct or timetable.
Ask the user:
ISO 532-1 (Zwicker, stationary/time-varying) or ISO 532-2 (Moore-Glasberg)?
Free-field or diffuse-field recording?
Time-varying analysis needed?
See references/psychoacoustic-metrics.md for method selection guidance (ISO 532-1 vs 532-2), interpretation tables (sone values, sharpness/roughness/fluctuation scales), tonality metric selection, and combined sound quality assessment workflows.
Unit Conversions
Use built-in functions — do NOT reimplement conversion formulas manually:
| Conversion | Function | Method selection |
|---|---|---|
| phon → sone | phon2sone(phon, standard) | "ISO 532-1" (default), "ISO 532-2" |
| sone → phon | sone2phon(sone, standard) | "ISO 532-1" (default), "ISO 532-2" |
| Hz → ERB | hz2erb(freq) | Single formula (no variants) |
| ERB → Hz | erb2hz(erb) | Single formula (no variants) |
| Hz → bark | hz2bark(freq) | Single formula (no variants) |
| bark → Hz | bark2hz(bark) | Single formula (no variants) |
| Hz → mel | hz2mel(freq, MelStyle=s) | "oshaughnessy" (default), "slaney" |
| mel → Hz | mel2hz(mel, MelStyle=s) | "oshaughnessy" (default), "slaney" |
When the user specifies a standard (e.g., "ISO 532-2"), pass it as the second positional argument for phon2sone/sone2phon. For hz2mel/mel2hz, use the MelStyle name-value pair.
Noise Compliance
Choose the function based on the application:
| Situation | Function | Why |
|---|---|---|
| General background noise rating | noiseCriteria | Standard NC curves (ANSI/ASA S12.2) |
| HVAC system noise specifically | roomCriteria | RC Mark II designed for HVAC evaluation |
| Noise with audible surging/fluctuation | roomNoiseCriteria | RNC penalizes time-varying noise (requires ≥15 s recording) |
| Quick speech interference check | speechInterferenceLevel | Direct SIL value |
| Need recommended levels for room type | noiseCriteriaRecommendations | Lookup table by room use |
[audioIn, fs] = audioread("office_noise.wav");
[NC, SIL, specImbalance, rattleRisk] = noiseCriteria(audioIn, fs, ...
CalibrationFactor=2.3);
[RC, LMF, QAI, rattleRisk] = roomCriteria(audioIn, fs, ...
CalibrationFactor=2.3);
SIL = speechInterferenceLevel(audioIn, fs, CalibrationFactor=2.3);
rec = noiseCriteriaRecommendations("NC", Occupancy="all");Return types:
NCis a string (e.g.,"NC-35"or"NC-56 (1000 Hz)"if a band exceeds)RCis a string (e.g.,"RC-32(N)"— the letter indicates spectrum quality: N/R/H/RV)SILandLMFare double scalars (dB)QAIis a double scalar (dB; 0 = ideal neutral)specImbalanceandrattleRiskare structs with.Summary(string) and.Details(table) — access.Summaryfor display. Exception:specImbalancedegrades to acharscalar (not a struct) when NC exceeds the curve range (e.g., "Above NC-70") or falls below NC-15. Guard withisstruct(specImbalance)before dot-indexing.noiseCriteriaRecommendationsrequires a criteria name argument:"NC","RNC", or"RC"
Ask the user:
What type of space? (office, classroom, hospital, concert hall)
Is the noise source HVAC? → prefer
roomCriteriaIs the noise steady or fluctuating? → if fluctuating, use
roomNoiseCriteria
See references/noise-compliance.md for detailed output interpretation and selection guidance.
Speech Quality
[degraded, fs] = audioread("processed_speech.wav");
[reference, ~] = audioread("reference_speech.wav");
mosScore = visqol(degraded, reference, fs, Mode="speech");
intelligibility = stoi(degraded, reference, fs);Critical: stoi and visqol argument order is (processed, reference, fs) — processed/degraded signal FIRST.
visqol modes: "speech" for narrowband/wideband speech (outputs 1-5 MOS), "audio" (default) for general audio.
STI/SII Measurement
Two methods are available for both speechTransmissionIndex and speechIntelligibilityIndex:
IR-based method (simpler — no alignment needed):
[ir, fs] = audioread("room_impulse_response.wav");
sti = speechTransmissionIndex(ir, fs);
sii = speechIntelligibilityIndex(ir, fs);Direct method (from test signals transmitted through the system):
fs = 48000;
reference = stipaExcitation(fs, Duration=15);
% Transmit reference through system, record as 'processed'
[processed, ~] = audioread("received_stipa.wav");
% IMPORTANT: Align signals before computing (see Signal Alignment)
processed = alignsignals(processed, reference);
sti = speechTransmissionIndex(processed, reference, fs);Ask the user:
Do they have an impulse response? → use IR method (simpler, no alignment needed)
Measuring live? → generate test signal, transmit, record, align, compute
STI or SII? STI for room/PA systems (IEC 60268-16); SII for hearing/communication (ANSI S3.5)
See references/sti-measurement.md for STI NV arguments, post-processing adjustment workflow (Annex M), test signal generation, and result interpretation. See references/sii-measurement.md for SII standard clause selection (5.1-5.3), BandImportanceFunction guidance, measurement positioning, and result interpretation.
SPL Measurement (Offline)
[audioIn, fs] = audioread("recording.wav");
spl = splMeter(SampleRate=fs, ...
Bandwidth="Full band", ...
FrequencyWeighting="A-weighting", ...
TimeWeighting="fast", ...
CalibrationFactor=2.3);
[Lt, Leq, Lpeak, Lmax] = spl(audioIn);
% For a single overall value, read the final row
fprintf("Leq: %.1f dB(A)\n", Leq(end));Valid Bandwidth values: "Full band" (overall level), "1 octave", "2/3 octave", "1/3 octave". There is no "broadband" option — use "Full band" for a single overall SPL value.
Output arity: All outputs (Lt, Leq, Lpeak, Lmax) have one row per input sample. For a 12-second file at 44.1 kHz, that is 539,648 rows. Never fprintf or disp the full output — it will hang. Instead:
Single overall value: read
Leq(end)(the final accumulated value)Time-interval readings: downsample to interval boundaries:
Leq(round(fs*T):round(fs*T):end, :)whereTis the desired interval in seconds
TimeInterval controls the integration window for Leq computation but does NOT reduce the number of output rows.
Do not manually compute 20*log10(rms(audioIn)/20e-6) — splMeter handles calibration, weighting, and time integration correctly per IEC 61672.
Multi-band (octave-band) SPL: Use splMeter with Bandwidth="1 octave" — do NOT use octaveFilterBank + manual dB conversion. Key properties for octave-band SPL:
[audioIn, fs] = audioread("recording.wav");
spl = splMeter(SampleRate=fs, ...
Bandwidth="1 octave", ...
FrequencyWeighting="Z-weighting", ...
TimeWeighting="fast", ...
FrequencyRange=[15 8000], ...
OctaveFilterOrder=8, ...
CalibrationFactor=2.3);
[Lt, Leq, Lpeak, Lmax] = spl(audioIn);
cf = getCenterFrequencies(spl);Critical gotchas for octave-band splMeter:
Property name is
OctaveFilterOrder(notFilterOrder).FilterOrderdoes not exist onsplMeter.FrequencyRangecompares against true center frequencies (fc = 1000 × 10^(3b/10)per IEC 61260), not nominal values. A band is included only if its true center falls within[lower, upper]. Bands below 1 kHz have true centers slightly above nominal (e.g., "63 Hz" = 63.10); bands above 1 kHz have true centers below nominal (e.g., "2 kHz" = 1995.26, "8 kHz" = 7943.28). Usefloor(true_center)for lower bounds andceil(true_center)for upper bounds. Common case "16 Hz to 8 kHz": use[15 8000]— the 16 Hz true center is 15.85 (so 15 ≤ 15.85 includes it) and 8 kHz true center is 7943 (so 8000 ≥ 7943 includes it). Do NOT use[16 8000]— this drops the 16 Hz band.Output is per-sample (see Output arity note above). Never print the full output. For time-interval readings, downsample:
Lt100ms = Lt(round(fs*0.1):round(fs*0.1):end, :);
See references/spl-measurement.md for weighting selection guidance (A/C/Z and fast/slow), SPL interpretation tables, occupational exposure limits, splMeter vs poctave equivalency, and common measurement scenarios.
Broadcast Loudness (EBU R 128)
[audioIn, fs] = audioread("broadcast_content.wav");
[loudness, loudnessRange] = integratedLoudness(audioIn, fs);
% Check compliance: target is -23 LUFS +/- 1 LU
isCompliant = abs(loudness - (-23)) <= 1;Use integratedLoudness for offline compliance checks. Use loudnessMeter for streaming/real-time monitoring (see matlab-process-streaming-audio).
RT60
[ir, fs] = audioread("room_ir.wav");
rtsummary = rt60(ir, fs, Bandwidth="1 octave");Ask the user:
What is the room type? (drives the target RT60)
Do they have an IR, or do they need to measure one?
T30 (standard) vs T20 (when noise floor limits dynamic range)?
See references/rt60-measurement.md for target RT60 values by space type, T20/T30/EDT interpretation, frequency-dependent analysis, and relationship to STI.
Tonality
[audioIn, fs] = audioread("machine_noise.wav");
[tnr, tnrFreq, isProminent] = acousticToneToNoiseRatio(audioIn, fs);
[pr, prFreq, isProminent] = acousticProminenceRatio(audioIn, fs);All outputs are empty (0×1) when no tonal components are detected. Check isempty(tnr) before indexing.
Standards-Compliant Filters (Custom Preprocessing)
The metric functions above perform standards-compliant filtering internally. Use standalone filter objects only for custom measurement workflows where no single metric function applies AND you do not need SPL output:
% A-weighting filter
wf = weightingFilter("A-weighting", fs);
weightedSignal = wf(audioIn);
% Octave-band filter bank (for waveform-level band decomposition only)
ofb = octaveFilterBank("1 octave", fs, ...
FrequencyRange=[31.5 16000], FilterOrder=8);
bandSignals = ofb(audioIn);If you need octave-band SPL levels, use splMeter with Bandwidth="1 octave" instead of octaveFilterBank + manual dB conversion. See the Multi-band SPL section above.
Signal Alignment
| Function | Internal alignment? | Action |
|---|---|---|
visqol | Yes | No action needed |
stoi | No | Align before calling |
speechTransmissionIndex | No | Align for direct method; IR method avoids issue |
speechIntelligibilityIndex | No | Align for direct method; IR method avoids issue |
For the direct (processed, reference, fs) method, always align signals:
processed = alignsignals(processed, reference);SII is more sensitive to misalignment than STI. At 50 ms delay: SII error ~0.016, STI negligible. At 200 ms: SII ~0.036, STI ~0.017. The IR-based (ir, fs) method avoids alignment issues entirely.
Common Mistakes
| Mistake | Why it fails | Correct approach |
|---|---|---|
Call pesq(reference, degraded, fs) | Function does not exist | visqol(degraded, reference, fs, Mode="speech") |
stoi(reference, processed, fs) | Wrong argument order | stoi(processed, reference, fs) — processed FIRST |
acousticFluctuationStrength(...) | Wrong function name | acousticFluctuation(audioIn, fs, calFactor) |
| Implement NC from scratch with hardcoded curves | Misses SIL, spectrum imbalance, rattle risk | noiseCriteria(audioIn, fs, CalibrationFactor=cf) |
20*log10(rms(x)/20e-6) for SPL | No weighting, no time integration, no calibration | splMeter with appropriate settings |
| Implement STI algorithm manually | ~100 lines, error-prone, misses NV options | speechTransmissionIndex(ir, fs) |
| Divide signal by calibration factor manually | Incorrect; factor is a multiplier, not a divisor | Pass as positional arg or CalibrationFactor=value |
| Skip alignment for direct STI/SII | Silent accuracy degradation | alignsignals(processed, reference) before calling |
Use acousticLoudness for broadcast loudness | Wrong standard (ISO 532 = sones, not LUFS) | integratedLoudness for EBU R 128 compliance |
string(rattleRisk) or fprintf("%s", specImbalance) | These are structs, not strings | Access .Summary field: rattleRisk.Summary |
specImbalance.Summary when NC is out of curve range | specImbalance degrades to char (not struct) when "Above NC-70" or below NC-15 | Guard: if isstruct(specImbalance), disp(specImbalance.Summary); end |
roomNoiseCriteria on recordings shorter than 15 s | ANSI/ASA S12.2-2019 requires ≥150 Lt samples at 100 ms intervals | Ensure recording is at least 15 seconds; use noiseCriteria for shorter clips |
round(NC) or arithmetic on NC/RC output | NC and RC are strings, not numbers | Use directly: fprintf("%s\n", NC) |
noiseCriteriaRecommendations() with no args | First argument (criteria name) is required | noiseCriteriaRecommendations("NC") |
loudness.OverallLoudness after acousticLoudness | Returns a scalar or vector, not a struct | Use directly: fprintf("%.1f sones\n", loudness) |
splMeter(..., FilterOrder=8) | Property does not exist on splMeter | Use OctaveFilterOrder=8 |
splMeter(..., FrequencyRange=[16 8000]) for 16 Hz–8 kHz | Drops 16 Hz band (true center is 15.85 Hz, which is below 16) | Use FrequencyRange=[15 8000] — use floor(true_center) for lower bound |
octaveFilterBank + 20*log10(rms(band)/pRef) for SPL | Manual, no time weighting, no calibration integration | Use splMeter with Bandwidth="1 octave" |
Treating splMeter output as a single value | All outputs have one row per input sample (e.g., 539k rows for 12s at 44.1 kHz) | Use Leq(end) for a single value, or downsample to interval boundaries |
Conventions
Always ask about the user's measurement goal before selecting a function
Always ask about calibration — recommend
calibrateMicrophonefor system-level accuracyDefault to
SoundField="free"for anechoic/outdoor,"diffuse"for reverberant roomsDefault to
Method="ISO 532-1"for loudness (Zwicker method, most common)Use IR-based methods for STI/SII when an impulse response is available (avoids alignment)
Pass
CalibrationFactorexplicitly rather than pre-scaling the signalFor noise compliance, prefer
roomCriteriafor HVAC andnoiseCriteriafor general background noise
Copyright 2026 The MathWorks, Inc.
Files
- ATTRIBUTION.mdAdded by AutoGineer1.1 KiB
- LICENSELicence file added by AutoGineer1.4 KiB
- SKILL.md22.7 KiB
- manifest.yaml444 B
- references/function-arguments.md7.3 KiB
- references/noise-compliance.md16.4 KiB
- references/psychoacoustic-metrics.md16.0 KiB
- references/rt60-measurement.md14.4 KiB
- references/sii-measurement.md16.9 KiB
- references/spl-measurement.md12.5 KiB
- references/sti-measurement.md14.0 KiB
references/rt60-measurement.md
RT60 Measurement
Guidance for selecting parameters, interpreting results, and guiding user workflows for rt60.
Intake Questions
1. What is the purpose?
| Purpose | What RT60 tells them |
|---|---|
| Room design verification | Does the finished room meet the acoustic design target? |
| Speech intelligibility assessment | Is the room too reverberant for speech? (RT60 > 1.5s generally problematic) |
| Music venue evaluation | Is the reverberance appropriate for the genre? |
| Noise control / absorption planning | How much absorption is needed to reduce RT60 to target? |
| Compliance with building standards | Does the room meet standards like BB93, ANSI S12.60? |
| STI context | Explaining why STI is low — reverberance is the usual culprit |
2. Do they have an impulse response?
Yes: Pass directly to
rt60(ir, fs)No, need to measure: See the
matlab-play-record-audioskill for the IR capture workflow (sweeptonegeneration, playback/recording through the room, andimpzestdeconvolution). This skill covers what to do with the IR once obtained.
IR requirements: The IR must include the noise floor — continue recording after the reverberation tail has fully decayed. The function assumes at least the last 10% of the IR duration corresponds to noise (used for noise floor estimation). For large reverberant spaces (churches, concert halls), use longer captures (3–5 s minimum).
3. What analysis bandwidth?
| Bandwidth | Output | When to use |
|---|---|---|
"1 octave" (default) | RT60 per octave band | Standard building acoustics, compliance checks, general room characterization |
"1/3 octave" | RT60 per 1/3-octave band | Detailed analysis, research, when absorption varies significantly within octave bands |
4. Noise compensation method
| Method | Behavior | When to use |
|---|---|---|
"truncate-correct" (default) | Lundby algorithm: estimates noise floor, truncates IR at noise intersection, compensates per ISO 3382-1 | Standard-compliant measurements; most situations |
"subtract-truncate-correct" | Additionally subtracts noise floor before truncation | When the noise floor is relatively high; shown to introduce less systematic error in noisy conditions (non-ISO) |
Default is appropriate for most users. Only suggest "subtract-truncate-correct" when IRs have marginal SNR and the user does not require strict ISO 3382-1 compliance.
5. Measurement conditions (ISO 3382-2)
ISO 3382-2 defines three measurement levels (Table 1, section 4.3):
| Level | Source-mic combinations | Source positions | Mic positions | Accuracy (octave) |
|---|---|---|---|---|
| Survey | ≥2 | ≥1 | ≥2 | ~10% |
| Engineering | ≥6 | ≥2 | ≥2 | ~5% |
| Precision | ≥12 | ≥2 | ≥3 | ~2.5% |
Position requirements (section 4.3.1):
Mic positions shall be at least half a wavelength apart (~2 m for typical frequency range)
Distance from mic to nearest reflecting surface (including floor) should preferably be at least a quarter wavelength (~1 m)
Minimum source-to-mic distance depends on room volume and expected RT60: d_min = 2×sqrt(V / (c×T))
Symmetric positions shall be avoided
Additional conditions:
Room state: Furnishings in place as intended for use (unfurnished rooms measure much longer RT60)
Background noise (section 5.2.1): Source level shall be at least 35 dB above background noise for T20, or 45 dB for T30
Reliability (ISO 3382-1 section 7.3): Results shall satisfy B×T > 16, where B is the filter bandwidth (Hz) and T is the measured reverberation time (s). Low-frequency bands with short RT60 may fail this criterion.
Interpreting RT60 Results
T20 vs T30 vs EDT
| Metric | Evaluation Range | What it represents |
|---|---|---|
| EDT (Early Decay Time) | 0 to −10 dB | Perceived reverberance — what listeners experience (first part of decay dominates perception) |
| T20 | −5 to −25 dB | Reverberation time extrapolated from 20 dB range — more robust to noise than T30 |
| T30 | −5 to −35 dB | Reverberation time from 30 dB range — more accurate but requires higher IR SNR |
Guidance:
EDT correlates best with subjective impression of reverberance — use when reporting "how reverberant the room feels"
T30 is the standard metric for compliance and design verification (ISO 3382 prefers T30 when SNR allows)
T20 is a fallback when background noise limits the usable decay range
Topt uses the decay range yielding the best linear fit while remaining 10 dB above the detected noise floor — useful when neither T20 nor T30 gives a clean fit
In a well-diffused room, EDT ≈ T20 ≈ T30. If they diverge significantly:
EDT << T20/T30: Strong early reflections followed by a long tail (common with localized absorption near source/receiver)
EDT >> T20/T30: Weak early field (unusual — check measurement)
Metrics return NaN when the detected noise floor does not allow 10 dB of headroom over the evaluation range — this indicates insufficient IR SNR for that metric in that band
Additional Output Metrics
The rt60 output table includes metrics beyond reverberation time that are useful for room quality assessment:
| Metric | Standard | Definition | Application |
|---|---|---|---|
| C50 | ISO 3382-1 | Clarity (50 ms cutoff) — early-to-late energy ratio (dB) | Speech clarity: C50 > 0 dB is generally acceptable; higher is clearer |
| C80 | ISO 3382-1 | Clarity (80 ms cutoff) — early-to-late energy ratio (dB) | Music clarity: C80 between −2 and +2 dB is optimal for most genres |
| D50 | ISO 3382-1 | Definition (50 ms cutoff) — early-to-total energy ratio (0 to 1) | Speech: D50 > 0.5 generally indicates adequate articulation |
| TS | ISO 3382-1 | Center time — center of gravity of the squared IR (seconds) | Lower TS = more early energy; correlates with clarity perception |
| DegreeOfNonLinearity | ISO 3382-2 B.2 | 1000×(1−r²) for the linear fit of each decay range (N-by-4 matrix: EDT, T20, T30, Topt) | Values 0–5 typical; high values suggest non-exponential decay |
| Curvature | ISO 3382-2 B.3 | 100 × (T30/T20 − 1) (signed) | Values −5 to 5 typical; magnitude indicates divergence between T20 and T30; sign indicates direction |
When to report which metrics:
Room design compliance: T30 (or T20), Curvature
Speech room assessment: T30, EDT, C50, D50
Music venue assessment: T30, EDT, C80, TS
Measurement quality check: DegreeOfNonLinearity, Curvature
Target RT60 Values by Space Type
| Space | Target RT60 (s) | Standard/Reference |
|---|---|---|
| Recording studio / control room | 0.2–0.4 | — |
| Classroom (≤283 m³) | ≤ 0.6 | ANSI S12.60, BB93 (UK) |
| Classroom (>283 m³) | ≤ 0.7 | ANSI S12.60 |
| Conference room | 0.4–0.7 | — |
| Lecture hall | 0.7–1.0 | — |
| Open plan office | 0.5–0.8 | — |
| Concert hall (symphony) | 1.8–2.2 | — |
| Concert hall (chamber music) | 1.4–1.8 | — |
| Opera house | 1.2–1.6 | — |
| Church (liturgical music) | 2.0–4.0 | — |
| Worship (speech-primary) | 0.8–1.2 | — |
| Hospital patient room | 0.4–0.6 | — |
RT60 vs Frequency
RT60 typically varies with frequency:
Low frequencies (125–250 Hz): Often longer (less absorption from typical materials at LF)
Mid frequencies (500–1000 Hz): Reference range — most targets are specified here
High frequencies (2000–8000 Hz): Often shorter due to air absorption and porous absorber effectiveness
Common patterns and implications:
| Pattern | Cause | Action |
|---|---|---|
| Flat across frequency | Well-treated room with broadband absorption | Ideal for speech and music |
| Rising at low frequency | Insufficient bass trapping | Add bass traps, panel absorbers, or membrane absorbers |
| Falling at high frequency | Excessive HF absorption or air absorption in large rooms | Normal for large volumes; add diffusion if HF liveness desired |
| Spike at one frequency | Room mode or resonance | Treat the specific mode with targeted absorption |
Relationship to STI
RT60 and STI are directly related — reverberation is the primary degrader of speech intelligibility in quiet rooms. Approximate STI for purely diffuse exponential-decay rooms with no ambient noise (computed using speechTransmissionIndex on synthetic IRs with AddOperationalAmbientNoise=false):
| RT60 (s) | Approximate STI | IEC 60268-16 Category |
|---|---|---|
| 0.5 | 0.74 | A |
| 1.0 | 0.60 | D |
| 1.5 | 0.50 | G |
| 2.0 | 0.44 | H–I |
| 3.0 | 0.36 | U |
| 5.0 | 0.27 | U |
Adding ambient noise can only reduce STI below these values.
If the user has STI concerns:
Short RT60 but low STI → noise is the dominant factor, not reverberation
Long RT60 and low STI → reduce RT60 with absorption (most effective intervention)
Use
rt60to diagnose, thenspeechTransmissionIndexto quantify the intelligibility impact
Assessing Measurement Quality
Use DegreeOfNonLinearity and Curvature from the output table to assess whether results are trustworthy:
DegreeOfNonLinearity (ξ): Defined as 1000×(1−r²), where r² is the correlation coefficient of the linear fit to the energy decay curve. ξ = 0 means a perfect linear fit (r² = 1). ISO 3382-2 B.2 states typical values are 0–5. To interpret as r²: r² = 1 − ξ/1000 (e.g., ξ = 5 → r² = 0.995).
Curvature: Quantifies the divergence between T30 and T20. Values near 0 indicate consistent decay; |Curvature| > 5 suggests coupled volumes or non-diffuse conditions (ISO 3382-2 B.3).
NaN values: If a metric returns NaN, the detected noise floor does not provide enough headroom for that evaluation range in that band — use a metric with a shorter evaluation range (T20 instead of T30) or re-record with a stronger source.
Common Scenarios
Scenario: Classroom Compliance Check
Obtain room IR (see
matlab-play-record-audiofor capture workflow; sine sweep method preferred for SNR)Compute:
rtsummary = rt60(ir, fs, Bandwidth="1 octave")Read T30 (or T20 if insufficient SNR) at 500 Hz, 1000 Hz, 2000 Hz
Average these three mid-frequency bands → this is the compliance metric
Compare to target: ANSI S12.60 requires ≤ 0.6 s for rooms ≤ 283 m³
Scenario: Diagnose Low STI
Measure STI:
speechTransmissionIndex(ir, fs, OperationalNoiseLevel="NC-35")If STI is low, measure RT60:
rtsummary = rt60(ir, fs)Examine frequency-dependent RT60 — which bands are too long?
Cross-reference with MTI output from STI: low MTI at specific bands + long RT60 at those bands = reverberation-driven problem
Recommend treatment: add absorption in the frequency bands where RT60 exceeds the target
Scenario: Concert Hall Evaluation
Measure at multiple source-receiver positions (≥6 per ISO 3382-1)
Compute per-position RT60 and EDT
Report: mean T30 across positions (spatial average), EDT for perceived character
Compare T30 to genre target (1.8–2.2 s for symphony, 1.4–1.8 for chamber)
Check frequency balance: flat or gently rising at LF is preferred for warmth
Troubleshooting
Visual inspection of decay curves
The primary troubleshooting step is to call rt60 with no output arguments to generate the convenience plot. The plot shows:
Top panel: RT60 values (EDT, T20, T30, Topt) across octave bands — click a band to inspect it
Bottom panel: The energy decay curve (EDC) for the selected band with linear fit lines overlaid
Inspect the fit lines against the EDC to identify:
Noise floor intersection — where the EDC flattens, indicating the usable decay range
Double-slope decay (coupled rooms) — a "hump" or change in slope in the tail, where energy from an adjacent coupled space arrives. This appears as a concave EDC that doesn't follow a single straight line.
Poor fit — the linear regression doesn't track the actual decay
Adjusting parameters for better fits
If the decay curves show poor fits, adjust FilterOrder, FilterDirection, and NoiseCompensation and monitor DegreeOfNonLinearity and Curvature to find the combination that best characterizes the decay:
| Parameter | Options | When to adjust |
|---|---|---|
FilterOrder | 2 (default), 4, 6, ... | Higher order gives sharper band separation — try when adjacent bands bleed energy |
FilterDirection | "forward" (default), "backward" | Backward filtering eliminates filter ringing at the start of the decay — try when EDT looks unreliable |
NoiseCompensation | "truncate-correct" (default), "subtract-truncate-correct" | Subtract mode reduces bias from high noise floors — try when T30 shows large DegreeOfNonLinearity |
Common issues
| Observation | Likely Cause | Action |
|---|---|---|
| T30 varies wildly between bands | Normal if room has frequency-dependent absorption | Expected behavior; focus on mid-frequency average for compliance |
| T30 > T20 by large margin | Noise floor contaminating the lower part of the decay | Trust T20; re-measure with higher source level if T30 needed |
| Large Curvature with concave EDC | Coupled room — energy returns from adjacent space | Report T20 (less affected); note coupled-room behavior in results |
| EDT much shorter than T30 | Strong early reflections near measurement position | Indicates non-diffuse field; measure at more positions and average |
| Very short RT60 (<0.1 s) | IR too short, or measurement captured direct sound only | Verify IR contains the full decay; use longer measurement window |
| RT60 result shows NaN or unreliable | Insufficient signal-to-noise ratio in that band | Check noise floor; use T20 instead of T30; re-record with stronger source |
| Different results from different positions | Normal room mode behavior — spatial variation is expected | Average across ≥3 positions per ISO 3382; report range |
| RT60 doesn't match subjective impression | EDT correlates better with perception than T30 | Report EDT alongside T30 for perceptual assessment |
| Measured RT60 seems implausible for the room | Measurement error, or unexpected room conditions | Use predictRT60 with known room dimensions and materials as a sanity check against the measured value |
Copyright 2026 The MathWorks, Inc.
Requirements and compatibility
Works with: Claude Code, Claude apps, OpenAI Codex, GitHub Copilot, Cursor, Gemini CLI, Kiro, OpenCode, Goose, Amp, Roo Code, JetBrains Junie, Factory Droid, Devin (ex-Windsurf), Mistral Vibe, OpenHands, Letta
“Works with” means the tool reads the open Agent Skills format; a skill written for one tool may use features others lack.
Security
No issues found by our static scan· No issues found
A static scan is not a guarantee. Skills are third-party content: review a skill before you let an agent use it.
Attribution and licence
- Created by
- MathWorks
- Publisher
- MathWorks (Official)
- Source
- matlab/matlab-agentic-toolkit · skills-catalog/signal-processing/matlab-evaluate-acoustic-metrics · commit 2a7f215
- Licence
- BSD 2-Clause License (redistribution allowed)
- LICENSE (added by AutoGineer from LICENSE.md)
- ATTRIBUTION.md (written by AutoGineer)
- Synced
AutoGineer is not affiliated with or endorsed by MathWorks or MathWorks.
Download ZIP
The ZIP holds the skill’s files, its licence files and an ATTRIBUTION.md. Download matlab-evaluate-acoustic-metrics.zip