Generated banner for Matlab Evaluate Acoustic Metrics
Generated logo for Matlab Evaluate Acoustic Metrics

Matlab Evaluate Acoustic Metrics

MathWorksOfficialCreated by MathWorks

  • Skill
  • Tool integration
  • Science and research
  • BSD-2-Clause
  • No issues found

From the author

Select and use Audio Toolbox acoustic, psychoacoustic, and speech quality metrics. Use when computing loudness, sharpness, roughness, fluctuation strength, noise criteria (NC/RNC/RC), speech transmission index (STI), speech intelligibility index (SII), speech quality (ViSQOL, STOI), SPL, reverberation time (RT60), tone-to-noise ratio, or prominence ratio. Also use when asked about PESQ, POLQA, calibration factor, EBU R 128, LUFS, HVAC noise, background noise evaluation, or how to measure audio quality or noise compliance. Covers calibration, standard selection, signal alignment, and the complete function inventory including what does NOT exist.
— the description by MathWorks

AutoGineer summary

Written by AutoGineer from the skill’s own files, not by the author

This skill provides a structured approach to using MATLAB Audio Toolbox for acoustic measurement and analysis. It guides users through selecting the correct functions for psychoacoustic metrics, speech intelligibility, noise compliance, and broadcast loudness. The skill emphasizes proper calibration techniques, standard-compliant workflows, and the correct handling of signal data to ensure accurate results, while explicitly warning against the use of nonexistent or licensed-restricted functions.

What it does

  • Calculates psychoacoustic metrics like loudness, sharpness, roughness, and fluctuation strength.
  • Evaluates speech quality and intelligibility using metrics such as ViSQOL, STOI, STI, and SII.
  • Assesses noise compliance using NC, RC, and RNC ratings for various environments.
  • Performs offline SPL measurements and broadcast loudness checks (EBU R 128).
  • Provides guidance on microphone calibration and system-level calibration factors.
  • Offers standard-compliant filtering and unit conversion utilities.

When to use it

  • When you need to measure perceived loudness or sound quality in a research or engineering context.
  • When evaluating room acoustics or HVAC noise compliance against industry standards.
  • When analyzing speech intelligibility for communication systems or public address setups.
  • When you need to calibrate audio recordings for accurate SPL or metric computation.
  • When you need to perform broadcast loudness compliance checks.

Advantages

  • Ensures adherence to international standards like ISO 532-1/2, ANSI/ASA S12.2, and IEC 60268-16.
  • Prevents common errors such as incorrect function usage, argument ordering, or manual implementation of complex algorithms.
  • Provides clear guidance on calibration to ensure measurement accuracy.
  • Streamlines the selection of appropriate metrics based on specific application goals.

Usage examples

“How do I calculate the loudness of a recording in sones?”
The agent will guide you to use the acousticLoudness function, specifying the ISO 532-1 method, applying your calibration factor, and selecting the appropriate sound field.
“Is my office HVAC noise compliant?”
The agent will recommend using the roomCriteria function to obtain an RC rating, explaining how to interpret the output and verify the measurement conditions.
“How can I measure the speech quality of a processed audio file?”
The agent will instruct you to use the visqol function with the 'speech' mode, ensuring the processed signal is passed as the first argument.
“How do I calibrate my microphone for SPL measurements?”
The agent will explain how to use calibrateMicrophone with a 1 kHz tone recording and a known SPL reference to compute the correct calibration factor.

Install

  1. Download the skill as a ZIP:

    https://autogineer.com/agent-skills/matlab/matlab-evaluate-acoustic-metrics/download
  2. Unzip it into the cross-client skills folder of your project:

    mkdir -p .agents/skills && unzip matlab-evaluate-acoustic-metrics.zip -d .agents/skills

Documentation by MathWorks

Evaluate Acoustic Metrics

Select the correct Audio Toolbox function for acoustic measurement, apply proper calibration, and choose appropriate standards — instead of reimplementing algorithms or calling nonexistent functions.

When to Use

  • Computing psychoacoustic metrics (loudness, sharpness, roughness, fluctuation)

  • Evaluating speech quality or intelligibility (ViSQOL, STOI, STI, SII)

  • Assessing noise compliance (NC rating, RC rating, RNC, SIL)

  • Measuring SPL from recordings (offline, calibrated)

  • Computing broadcast loudness (EBU R 128 / LUFS)

  • Measuring reverberation time (RT60) from impulse responses

  • Detecting tonal content (tone-to-noise ratio, prominence ratio)

  • Converting microphone sensitivity to CalibrationFactor

  • User mentions PESQ or POLQA (redirect to correct alternatives)

When NOT to Use

  • Real-time streaming audio processing loops — use matlab-process-streaming-audio

  • Audio device I/O, recording, or live calibrateMicrophone — use matlab-play-record-audio

  • Audio plugin authoring (VST/AU) — use matlab-write-audio-plugin

  • General filter design unrelated to measurement — use matlab-design-digital-filter

  • Spatial audio / HRTF / SOFA processing

Workflow

Follow this decision tree to route the user's goal to the right function:

1. Identify the measurement goal
GoalCategoryGo to
"How loud is it?" (perceived)Psychoacoustic→ Psychoacoustic Metrics
"Does it comply with broadcast loudness?"Broadcast→ Broadcast Loudness
"Is the noise level acceptable for this space?"Noise compliance→ Noise Compliance
"Can people understand speech in this room?"Speech intelligibility→ STI/SII Measurement
"How good does processed speech sound?"Speech quality→ Speech Quality
"What's the SPL?"Level measurement→ SPL Measurement
"What's the reverberation time?"Room acoustics→ RT60
"Is there a tonal component?"Tonality→ Tonality
2. Ask before computing

Before writing code, confirm these with the user:

  • Calibration: Do they have a CalibrationFactor? Did they calibrate with calibrateMicrophone? (See Calibration section)

  • Standard: Which standard or method applies? (ISO 532-1 vs 532-2, NC vs RC vs RNC)

  • Sound field: Free field or diffuse field recording?

  • Application context: What space type? What's the concern? (Drives NC vs RC vs RNC selection)

3. Select function and apply

Use the Key Functions table and the category-specific patterns below.

Functions That Do NOT Exist

FunctionStatusUse Instead
pesqDoes NOT exist (proprietary ITU-T P.862 license)visqol(degraded, reference, fs, Mode="speech")
polqaDoes NOT exist (proprietary ITU-T P.863 license)visqol(degraded, reference, fs)

Never suggest pesq or polqa. They are not in Audio Toolbox and cannot be added due to licensing.

Key Functions

FunctionPurposeStandardAvailable From
acousticLoudnessPerceived loudness (sones)ISO 532-1/2R2020a
acousticSharpnessPerceived sharpness (acum)DIN 45692R2020a
acousticRoughnessPerceived roughness (asper)—R2021a
acousticFluctuationFluctuation strength (vacil)—R2020b
integratedLoudnessBroadcast loudness (LUFS)EBU R 128 / ITU-R BS.1770R2016b
loudnessMeterStreaming broadcast loudness meterEBU R 128 / ITU-R BS.1770R2018a
visqolFull-reference audio quality (MOS)—R2024a
stoiShort-time objective intelligibility—R2024a
mnruModulated noise reference unitITU-T P.810R2024a
dBovPower level relative to overload (dB)ITU-T G.100.1R2024a
speechTransmissionIndexSTI from IR or test signalsIEC 60268-16R2026a
speechIntelligibilityIndexSII from IR, test signals, or levelsANSI/ASA S3.5-1997R2026b
stipaExcitationGenerate STI/STIPA test signalsIEC 60268-16R2026a
siiExcitationGenerate SII test signalsANSI/ASA S3.5-1997R2026b
noiseCriteriaNC rating + SIL + spectrum imbalance + rattle riskANSI/ASA S12.2R2026b
roomNoiseCriteriaRNC rating (detects surging/fluctuations)ANSI/ASA S12.2R2026b
roomCriteriaRC Mark II rating (HVAC systems)ANSI/ASA S12.2R2026b
noiseCriteriaCurvesLook up NC curve valuesANSI/ASA S12.2R2026b
noiseCriteriaRecommendationsRecommended NC levels by room typeANSI/ASA S12.2R2026b
speechInterferenceLevelSIL from recordingANSI/ASA S12.2R2026b
rt60Reverberation time from impulse responseISO 3382-1/2R2025a
acousticToneToNoiseRatioDetect/quantify tonesECMA-418-1R2023b
acousticProminenceRatioTonality via critical band comparisonECMA-418-1R2023b
splMeterSPL measurement (time-weighted, per-band)IEC 61672R2018a
calibrateMicrophoneCompute calibration factor from known tone—R2018b
weightingFilterA/C/Z/K frequency weightingIEC 61672-1R2016b
octaveFilterSingle octave-band filterANSI S1.11-2004R2017b
octaveFilterBankMulti-band octave filteringANSI S1.11-2004R2019a

See references/function-arguments.md for complete argument lists, defaults, and valid values for each function — consult when constructing calls with non-default parameters.

Calibration

CalibrationFactor from microphone sensitivity

Convert dB sensitivity (dBV/Pa) to the linear CalibrationFactor:

sensitivity_dBV = -26;  % Example: -26 dBV/Pa microphone
calibrationFactor = 1 / 10^(sensitivity_dBV/20);

The CalibrationFactor is the 3rd positional argument for acousticLoudness, acousticSharpness, acousticRoughness, and acousticFluctuation (default: sqrt(8)). For noise compliance functions, pass it as a name-value: CalibrationFactor=value.

System-level calibration advice

Always ask the user about their signal chain. If the recording path includes a preamp, audio interface, or ADC with unknown gain, the mic sensitivity spec alone is insufficient. Recommend:

  1. Play a 1 kHz tone through the system and record it through the full signal chain (mic → preamp → ADC → WAV). Use a pistonphone for a known 94 dB reference, or place a physical SPL meter next to the microphone to get an SPL reading.

  2. Compute the system calibration factor: calibrationFactor = calibrateMicrophone(calRecording, fs, SPLreading, FrequencyWeighting="Z-weighting")

  3. Pass that factor to the measurement function

calibrateMicrophone expects a 1 kHz tone recording as input. The SPLreading argument is the known SPL in dB (e.g., 94 from a pistonphone, or the value shown on a physical SPL meter).

Cross-reference: for the physical recording workflow with calibrateMicrophone, see the matlab-play-record-audio skill.

Patterns

Psychoacoustic Metrics
[audioIn, fs] = audioread("recording.wav");
calFactor = 1 / 10^(-26/20);

loudness = acousticLoudness(audioIn, fs, calFactor, ...
    Method="ISO 532-1", SoundField="diffuse", TimeVarying=true);

sharpness = acousticSharpness(audioIn, fs, calFactor, ...
    SoundField="diffuse", TimeVarying=true);

roughness = acousticRoughness(audioIn, fs, calFactor, SoundField="diffuse");

fluctuation = acousticFluctuation(audioIn, fs, calFactor, SoundField="diffuse");

Return types: acousticLoudness returns a scalar (sones) for stationary analysis. With TimeVarying=true, it returns a column vector (time-varying loudness in sones). The second output (specificLoudness) is a matrix (time x critical bands). It does NOT return a struct or timetable.

Ask the user:

  • ISO 532-1 (Zwicker, stationary/time-varying) or ISO 532-2 (Moore-Glasberg)?

  • Free-field or diffuse-field recording?

  • Time-varying analysis needed?

See references/psychoacoustic-metrics.md for method selection guidance (ISO 532-1 vs 532-2), interpretation tables (sone values, sharpness/roughness/fluctuation scales), tonality metric selection, and combined sound quality assessment workflows.

Unit Conversions

Use built-in functions — do NOT reimplement conversion formulas manually:

ConversionFunctionMethod selection
phon → sonephon2sone(phon, standard)"ISO 532-1" (default), "ISO 532-2"
sone → phonsone2phon(sone, standard)"ISO 532-1" (default), "ISO 532-2"
Hz → ERBhz2erb(freq)Single formula (no variants)
ERB → Hzerb2hz(erb)Single formula (no variants)
Hz → barkhz2bark(freq)Single formula (no variants)
bark → Hzbark2hz(bark)Single formula (no variants)
Hz → melhz2mel(freq, MelStyle=s)"oshaughnessy" (default), "slaney"
mel → Hzmel2hz(mel, MelStyle=s)"oshaughnessy" (default), "slaney"

When the user specifies a standard (e.g., "ISO 532-2"), pass it as the second positional argument for phon2sone/sone2phon. For hz2mel/mel2hz, use the MelStyle name-value pair.

Noise Compliance

Choose the function based on the application:

SituationFunctionWhy
General background noise ratingnoiseCriteriaStandard NC curves (ANSI/ASA S12.2)
HVAC system noise specificallyroomCriteriaRC Mark II designed for HVAC evaluation
Noise with audible surging/fluctuationroomNoiseCriteriaRNC penalizes time-varying noise (requires ≥15 s recording)
Quick speech interference checkspeechInterferenceLevelDirect SIL value
Need recommended levels for room typenoiseCriteriaRecommendationsLookup table by room use
[audioIn, fs] = audioread("office_noise.wav");

[NC, SIL, specImbalance, rattleRisk] = noiseCriteria(audioIn, fs, ...
    CalibrationFactor=2.3);

[RC, LMF, QAI, rattleRisk] = roomCriteria(audioIn, fs, ...
    CalibrationFactor=2.3);

SIL = speechInterferenceLevel(audioIn, fs, CalibrationFactor=2.3);

rec = noiseCriteriaRecommendations("NC", Occupancy="all");

Return types:

  • NC is a string (e.g., "NC-35" or "NC-56 (1000 Hz)" if a band exceeds)

  • RC is a string (e.g., "RC-32(N)" — the letter indicates spectrum quality: N/R/H/RV)

  • SIL and LMF are double scalars (dB)

  • QAI is a double scalar (dB; 0 = ideal neutral)

  • specImbalance and rattleRisk are structs with .Summary (string) and .Details (table) — access .Summary for display. Exception: specImbalance degrades to a char scalar (not a struct) when NC exceeds the curve range (e.g., "Above NC-70") or falls below NC-15. Guard with isstruct(specImbalance) before dot-indexing.

  • noiseCriteriaRecommendations requires a criteria name argument: "NC", "RNC", or "RC"

Ask the user:

  • What type of space? (office, classroom, hospital, concert hall)

  • Is the noise source HVAC? → prefer roomCriteria

  • Is the noise steady or fluctuating? → if fluctuating, use roomNoiseCriteria

See references/noise-compliance.md for detailed output interpretation and selection guidance.

Speech Quality
[degraded, fs] = audioread("processed_speech.wav");
[reference, ~] = audioread("reference_speech.wav");

mosScore = visqol(degraded, reference, fs, Mode="speech");

intelligibility = stoi(degraded, reference, fs);

Critical: stoi and visqol argument order is (processed, reference, fs) — processed/degraded signal FIRST.

visqol modes: "speech" for narrowband/wideband speech (outputs 1-5 MOS), "audio" (default) for general audio.

STI/SII Measurement

Two methods are available for both speechTransmissionIndex and speechIntelligibilityIndex:

IR-based method (simpler — no alignment needed):

[ir, fs] = audioread("room_impulse_response.wav");
sti = speechTransmissionIndex(ir, fs);
sii = speechIntelligibilityIndex(ir, fs);

Direct method (from test signals transmitted through the system):

fs = 48000;
reference = stipaExcitation(fs, Duration=15);
% Transmit reference through system, record as 'processed'
[processed, ~] = audioread("received_stipa.wav");

% IMPORTANT: Align signals before computing (see Signal Alignment)
processed = alignsignals(processed, reference);

sti = speechTransmissionIndex(processed, reference, fs);

Ask the user:

  • Do they have an impulse response? → use IR method (simpler, no alignment needed)

  • Measuring live? → generate test signal, transmit, record, align, compute

  • STI or SII? STI for room/PA systems (IEC 60268-16); SII for hearing/communication (ANSI S3.5)

See references/sti-measurement.md for STI NV arguments, post-processing adjustment workflow (Annex M), test signal generation, and result interpretation. See references/sii-measurement.md for SII standard clause selection (5.1-5.3), BandImportanceFunction guidance, measurement positioning, and result interpretation.

SPL Measurement (Offline)
[audioIn, fs] = audioread("recording.wav");

spl = splMeter(SampleRate=fs, ...
    Bandwidth="Full band", ...
    FrequencyWeighting="A-weighting", ...
    TimeWeighting="fast", ...
    CalibrationFactor=2.3);

[Lt, Leq, Lpeak, Lmax] = spl(audioIn);

% For a single overall value, read the final row
fprintf("Leq: %.1f dB(A)\n", Leq(end));

Valid Bandwidth values: "Full band" (overall level), "1 octave", "2/3 octave", "1/3 octave". There is no "broadband" option — use "Full band" for a single overall SPL value.

Output arity: All outputs (Lt, Leq, Lpeak, Lmax) have one row per input sample. For a 12-second file at 44.1 kHz, that is 539,648 rows. Never fprintf or disp the full output — it will hang. Instead:

  • Single overall value: read Leq(end) (the final accumulated value)

  • Time-interval readings: downsample to interval boundaries: Leq(round(fs*T):round(fs*T):end, :) where T is the desired interval in seconds

TimeInterval controls the integration window for Leq computation but does NOT reduce the number of output rows.

Do not manually compute 20*log10(rms(audioIn)/20e-6) — splMeter handles calibration, weighting, and time integration correctly per IEC 61672.

Multi-band (octave-band) SPL: Use splMeter with Bandwidth="1 octave" — do NOT use octaveFilterBank + manual dB conversion. Key properties for octave-band SPL:

[audioIn, fs] = audioread("recording.wav");

spl = splMeter(SampleRate=fs, ...
    Bandwidth="1 octave", ...
    FrequencyWeighting="Z-weighting", ...
    TimeWeighting="fast", ...
    FrequencyRange=[15 8000], ...
    OctaveFilterOrder=8, ...
    CalibrationFactor=2.3);

[Lt, Leq, Lpeak, Lmax] = spl(audioIn);
cf = getCenterFrequencies(spl);

Critical gotchas for octave-band splMeter:

  • Property name is OctaveFilterOrder (not FilterOrder). FilterOrder does not exist on splMeter.

  • FrequencyRange compares against true center frequencies (fc = 1000 × 10^(3b/10) per IEC 61260), not nominal values. A band is included only if its true center falls within [lower, upper]. Bands below 1 kHz have true centers slightly above nominal (e.g., "63 Hz" = 63.10); bands above 1 kHz have true centers below nominal (e.g., "2 kHz" = 1995.26, "8 kHz" = 7943.28). Use floor(true_center) for lower bounds and ceil(true_center) for upper bounds. Common case "16 Hz to 8 kHz": use [15 8000] — the 16 Hz true center is 15.85 (so 15 ≤ 15.85 includes it) and 8 kHz true center is 7943 (so 8000 ≥ 7943 includes it). Do NOT use [16 8000] — this drops the 16 Hz band.

  • Output is per-sample (see Output arity note above). Never print the full output. For time-interval readings, downsample: Lt100ms = Lt(round(fs*0.1):round(fs*0.1):end, :);

See references/spl-measurement.md for weighting selection guidance (A/C/Z and fast/slow), SPL interpretation tables, occupational exposure limits, splMeter vs poctave equivalency, and common measurement scenarios.

Broadcast Loudness (EBU R 128)
[audioIn, fs] = audioread("broadcast_content.wav");
[loudness, loudnessRange] = integratedLoudness(audioIn, fs);

% Check compliance: target is -23 LUFS +/- 1 LU
isCompliant = abs(loudness - (-23)) <= 1;

Use integratedLoudness for offline compliance checks. Use loudnessMeter for streaming/real-time monitoring (see matlab-process-streaming-audio).

RT60
[ir, fs] = audioread("room_ir.wav");
rtsummary = rt60(ir, fs, Bandwidth="1 octave");

Ask the user:

  • What is the room type? (drives the target RT60)

  • Do they have an IR, or do they need to measure one?

  • T30 (standard) vs T20 (when noise floor limits dynamic range)?

See references/rt60-measurement.md for target RT60 values by space type, T20/T30/EDT interpretation, frequency-dependent analysis, and relationship to STI.

Tonality
[audioIn, fs] = audioread("machine_noise.wav");

[tnr, tnrFreq, isProminent] = acousticToneToNoiseRatio(audioIn, fs);

[pr, prFreq, isProminent] = acousticProminenceRatio(audioIn, fs);

All outputs are empty (0×1) when no tonal components are detected. Check isempty(tnr) before indexing.

Standards-Compliant Filters (Custom Preprocessing)

The metric functions above perform standards-compliant filtering internally. Use standalone filter objects only for custom measurement workflows where no single metric function applies AND you do not need SPL output:

% A-weighting filter
wf = weightingFilter("A-weighting", fs);
weightedSignal = wf(audioIn);

% Octave-band filter bank (for waveform-level band decomposition only)
ofb = octaveFilterBank("1 octave", fs, ...
    FrequencyRange=[31.5 16000], FilterOrder=8);
bandSignals = ofb(audioIn);

If you need octave-band SPL levels, use splMeter with Bandwidth="1 octave" instead of octaveFilterBank + manual dB conversion. See the Multi-band SPL section above.

Signal Alignment

FunctionInternal alignment?Action
visqolYesNo action needed
stoiNoAlign before calling
speechTransmissionIndexNoAlign for direct method; IR method avoids issue
speechIntelligibilityIndexNoAlign for direct method; IR method avoids issue

For the direct (processed, reference, fs) method, always align signals:

processed = alignsignals(processed, reference);

SII is more sensitive to misalignment than STI. At 50 ms delay: SII error ~0.016, STI negligible. At 200 ms: SII ~0.036, STI ~0.017. The IR-based (ir, fs) method avoids alignment issues entirely.

Common Mistakes

MistakeWhy it failsCorrect approach
Call pesq(reference, degraded, fs)Function does not existvisqol(degraded, reference, fs, Mode="speech")
stoi(reference, processed, fs)Wrong argument orderstoi(processed, reference, fs) — processed FIRST
acousticFluctuationStrength(...)Wrong function nameacousticFluctuation(audioIn, fs, calFactor)
Implement NC from scratch with hardcoded curvesMisses SIL, spectrum imbalance, rattle risknoiseCriteria(audioIn, fs, CalibrationFactor=cf)
20*log10(rms(x)/20e-6) for SPLNo weighting, no time integration, no calibrationsplMeter with appropriate settings
Implement STI algorithm manually~100 lines, error-prone, misses NV optionsspeechTransmissionIndex(ir, fs)
Divide signal by calibration factor manuallyIncorrect; factor is a multiplier, not a divisorPass as positional arg or CalibrationFactor=value
Skip alignment for direct STI/SIISilent accuracy degradationalignsignals(processed, reference) before calling
Use acousticLoudness for broadcast loudnessWrong standard (ISO 532 = sones, not LUFS)integratedLoudness for EBU R 128 compliance
string(rattleRisk) or fprintf("%s", specImbalance)These are structs, not stringsAccess .Summary field: rattleRisk.Summary
specImbalance.Summary when NC is out of curve rangespecImbalance degrades to char (not struct) when "Above NC-70" or below NC-15Guard: if isstruct(specImbalance), disp(specImbalance.Summary); end
roomNoiseCriteria on recordings shorter than 15 sANSI/ASA S12.2-2019 requires ≥150 Lt samples at 100 ms intervalsEnsure recording is at least 15 seconds; use noiseCriteria for shorter clips
round(NC) or arithmetic on NC/RC outputNC and RC are strings, not numbersUse directly: fprintf("%s\n", NC)
noiseCriteriaRecommendations() with no argsFirst argument (criteria name) is requirednoiseCriteriaRecommendations("NC")
loudness.OverallLoudness after acousticLoudnessReturns a scalar or vector, not a structUse directly: fprintf("%.1f sones\n", loudness)
splMeter(..., FilterOrder=8)Property does not exist on splMeterUse OctaveFilterOrder=8
splMeter(..., FrequencyRange=[16 8000]) for 16 Hz–8 kHzDrops 16 Hz band (true center is 15.85 Hz, which is below 16)Use FrequencyRange=[15 8000] — use floor(true_center) for lower bound
octaveFilterBank + 20*log10(rms(band)/pRef) for SPLManual, no time weighting, no calibration integrationUse splMeter with Bandwidth="1 octave"
Treating splMeter output as a single valueAll outputs have one row per input sample (e.g., 539k rows for 12s at 44.1 kHz)Use Leq(end) for a single value, or downsample to interval boundaries

Conventions

  • Always ask about the user's measurement goal before selecting a function

  • Always ask about calibration — recommend calibrateMicrophone for system-level accuracy

  • Default to SoundField="free" for anechoic/outdoor, "diffuse" for reverberant rooms

  • Default to Method="ISO 532-1" for loudness (Zwicker method, most common)

  • Use IR-based methods for STI/SII when an impulse response is available (avoids alignment)

  • Pass CalibrationFactor explicitly rather than pre-scaling the signal

  • For noise compliance, prefer roomCriteria for HVAC and noiseCriteria for general background noise


Copyright 2026 The MathWorks, Inc.


Files

references/noise-compliance.md

Noise Compliance Function Family

Intake Questions

Before writing code, ask the user about these topics to select the right function and parameters:

1. What is the noise source?
SourceImplication
HVAC (fans, ducts, diffusers)Use roomCriteria for spectral quality; noiseCriteria for compliance
Variable-speed drives or cycling equipmentUse roomNoiseCriteria — fluctuation penalty likely applies
General background (multiple sources)Use noiseCriteria for a standard NC rating
Unknown / complaint investigationRun all three methods and compare
2. What is the space type?

Needed for selecting a design target. Common targets (from ANSI/ASA S12.2-2019 Tables C.1/C.2/C.3/D.2):

OccupancyNC/RNC TargetRC TargetA-weighted Target (dBA)
Concert hall / recording studio15–20RC 15–20 (N)—
Courtroom / lecture hall25–30RC 25–30 (N)39–44
Private office / conference room25–35RC 25–35 (N)44–48
Classroom25–30RC 25–30 (N)35
Open plan office35–45RC 35–45 (N)44–48
Hospital patient room25–35RC 25–35 (N)35–39
Restaurant / cafeteria40–45RC 40–45 (N)48–52

NC and RNC share the same recommendation targets — use RNC in place of NC when temporal variation is a concern. RC targets are from a separate table with different occupancy categories.

Use noiseCriteriaRecommendations("NC"), noiseCriteriaRecommendations("RC"), or noiseCriteriaRecommendations("A-weighted") for the full table with all occupancy types.

3. Is the noise steady or fluctuating?
  • Steady: NC or RC is sufficient

  • Fluctuating (surging, throbbing, cycling): Use roomNoiseCriteria — it penalizes temporal variation that NC misses. RNC ≥ NC always (RNC is stricter). If RNC significantly exceeds NC, the fluctuation is the problem.

  • Unsure: Record ≥15 s and run both noiseCriteria and roomNoiseCriteria; compare the ratings

4. What is the goal?
GoalApproach
Simple compliance check against specnoiseCriteria → compare to target
Diagnose spectral problems in HVACroomCriteria → read QAI and classification
Investigate occupant complaintsRun all three; compare NC vs RNC for fluctuation penalty
Set design targets for new constructionnoiseCriteriaRecommendations → specify in contract
Determine if noise affects speechspeechInterferenceLevel or SIL output from noiseCriteria
5. Measurement conditions

Confirm with the user:

  • Calibration: Do they have a calibration factor? (See main skill for conversion from dB sensitivity)

  • Recording duration: ≥15 s recommended for roomNoiseCriteria. The function will error on shorter recordings if surging or large random fluctuations are detected (the correction algorithm requires 150 Lt samples at 100 ms intervals, per clause 5.3.4). Shorter recordings pass if neither condition is detected. noiseCriteria and roomCriteria have no minimum duration requirement.

  • Room conditions: HVAC systems should be operating at normal design conditions, room unoccupied but furnished, doors/windows closed

  • Microphone position: Ear height of typical occupant (seated ~1.2 m, standing ~1.5 m). Either measure at a specific position to be characterized, or sweep slowly throughout the space while remaining at least 0.6 m from any one surface, 1.2 m from the intersection of two surfaces, and 2.4 m from the intersection of three surfaces.

Note: these measurement conditions are for strict compliance with the standard. The functions accept any calibrated recording — the conditions affect the validity of the result, not the ability of the function to compute it.

Function Selection

FunctionStandardBest ForKey Outputs
noiseCriteriaANSI/ASA S12.2-2019 (NC)General background noise assessmentNC level, SIL, spectrum imbalance, rattle risk
roomNoiseCriteriaANSI/ASA S12.2-2019 (RNC)Noise with audible temporal variationRNC level, rattle risk
roomCriteriaANSI/ASA S12.2-2019 (RC Mark II)HVAC system noise evaluationRC level, LMF, QAI, rattle risk
speechInterferenceLevelANSI/ASA S12.65-2006Quick speech interference checkSIL value (dB)
noiseCriteriaCurvesANSI/ASA S12.2-2019Look up NC curve SPL valuesSPL values at octave bands for given NC level
noiseCriteriaRecommendationsANSI/ASA S12.2-2019Find target NC/RC/dBA for room typeRecommended range for specified room use

Plotting: All noise compliance functions (noiseCriteria, roomCriteria, roomNoiseCriteria, noiseCriteriaCurves) produce a plot when called with no output arguments. Use this to visualize the measurement against reference curves. Encourage users to plot results for visual inspection.

Syntax and Outputs

noiseCriteria

Default choice for background noise assessment. Returns four outputs:

[NC, SIL, spectrumImbalance, rattleRisk] = noiseCriteria(audioIn, fs, ...
    CalibrationFactor=calFactor);
  • NC — NC level as string (e.g., "NC-35")

  • SIL — Speech interference level (average of 500/1k/2k/4k Hz bands)

  • spectrumImbalance — Structure with Summary (string) and Details (table showing deviation from reference NC curve per band)

  • rattleRisk — Structure with Summary (string) and Details (table showing measured levels vs. perceptibility thresholds)

Name-value arguments:

  • CalibrationFactor — Microphone calibration factor (default: 1)

  • PressureReference — Reference pressure in Pa (default: 20e-6)

  • ScreenSurging — Auto-detect surging in signal (default: true). Non-standard heuristic — per clause 5.3.2.1, surging should be detected by the user by listening or watching a meter for oscillations in low frequencies. Use this screening as a convenience, but inform users it is not a replacement for subjective assessment.

  • ScreenLargeRandomFluctuations — Auto-detect fluctuations (default: true). Uses the algorithmic method from the standard — users can have confidence in this screening.

Can also accept pre-computed octave-band Leq values: noiseCriteria(Leq) where Leq is a 1-by-10 row vector (octave bands 16 Hz to 8 kHz).

roomCriteria

Preferred for HVAC noise specifically. The RC Mark II method adds a Quality Assessment Index (QAI) that characterizes the noise spectrum as neutral, rumbly, hissy, or vibratory:

[RC, LMF, QAI, rattleRisk] = roomCriteria(audioIn, fs, ...
    CalibrationFactor=calFactor);
  • RC — RC level as string (e.g., "RC-32(N)" — the letter indicates spectrum quality)

  • LMF — Mid-frequency average (arithmetic mean of 500/1k/2k Hz octave bands)

  • QAI — Quality Assessment Index (lower is better; 0 = ideal neutral spectrum)

  • rattleRisk — Structure with rattle risk assessment

The spectrum quality descriptor appended to RC:

  • (N) — Neutral: balanced spectrum, no corrections needed

  • (R) — Rumble: excessive low-frequency energy

  • (H) — Hiss: excessive high-frequency energy

  • (RV) — Rumble with vibration risk

roomNoiseCriteria

Use when the noise has audible temporal variation (surging, random fluctuations). RNC is a stricter criterion than NC — it penalizes unsteady noise. Returns 2 outputs (not 4 like noiseCriteria):

[RNC, rattleRisk] = roomNoiseCriteria(audioIn, fs, ...
    CalibrationFactor=calFactor);

Minimum duration: ≥15 s recommended. The function errors on shorter recordings if surging or large random fluctuations are detected (the correction requires 150 Lt samples at 100 ms). Shorter recordings pass if neither condition is present.

Name-value arguments:

  • IsSurging — "auto-detect" (default), true, or false. The surging detection algorithm is a non-standard heuristic. Per clause 5.3.2.1, surging should be identified by the user by listening or watching a meter for oscillations in low frequencies.

  • IsFluctuating — "auto-detect" (default), true, or false. This uses the algorithmic method from the standard.

Can also accept pre-computed measurements: roomNoiseCriteria(Leq, Lt) where Lt is an N-by-10 matrix of fast time-weighted SPL measurements (100 ms intervals, one row per time step). Lt must use fast time-weighting.

speechInterferenceLevel

Simplest metric for speech interference — returns just the SIL value:

SIL = speechInterferenceLevel(audioIn, fs, CalibrationFactor=calFactor);

Supports time-varying output via TimeInterval:

SIL = speechInterferenceLevel(audioIn, fs, ...
    CalibrationFactor=calFactor, TimeInterval=1);
noiseCriteriaCurves

Look up SPL values for NC, RNC, or RC curves at standard octave-band center frequencies:

spl = noiseCriteriaCurves("NC", CurveID=35);
spl = noiseCriteriaCurves("RNC", CurveID=[25 30 35 40]);

First argument is the criteria name: "NC", "RNC", or "RC" (required). CurveID selects specific curve levels.

The function can return values outside the published standard range (e.g., below NC-15 or above NC-70) for flexibility and implementation robustness. The standard only defines curves within its published range.

Calling with no output arguments plots the curve family. Set the Parent argument to place the plot axes in a desired Axes, UIAxes, or Panel — useful as a building block in larger visual metering displays and applications.

noiseCriteriaRecommendations

Look up recommended noise criteria levels by occupancy/room type:

rec = noiseCriteriaRecommendations("NC");
rec = noiseCriteriaRecommendations("RC", Occupancy="Private offices");
rec = noiseCriteriaRecommendations("A-weighted");

First argument is the criteria name: "NC", "RNC", "RC", or "A-weighted" (required). Do NOT call with zero arguments or with a room-type string as the first argument.

Output Types

All noise compliance functions return strings and structs — not plain numerics for the rating outputs:

OutputTypeExample
NCstring"NC-35" or "NC-56 (1000 Hz)" (band shown if one exceeds)
RCstring"RC-32(N)", "RC-47 (H)" (letter = spectrum quality: N/R/H/RV)
RNCstring"RNC-38"
SIL, LMF, QAIdoubleScalar values in dB
specImbalancestruct or char.Summary (string) and .Details (table) — see note below
rattleRiskstruct.Summary (string) and .Details (table)

To display struct outputs, access the .Summary field: fprintf("Rattle: %s\n", rattleRisk.Summary). Do NOT pass the struct directly to string() or fprintf %s.

Edge case: specImbalance degrades to a plain char string (not a struct) when NC exceeds the curve range (e.g., "Above NC-70") or falls below NC-15 — spectrum imbalance is undefined in both cases. Always guard before dot-indexing:

if isstruct(specImbalance)
    fprintf("Imbalance: %s\n", specImbalance.Summary);
else
    fprintf("Imbalance: %s\n", specImbalance);
end

Input Flexibility

All noise compliance functions accept either:

  • Raw audio + sample rate: func(audioIn, fs, CalibrationFactor=cf) — computes octave-band Leq internally

  • Pre-computed octave-band Leq: func(Leq) — a 1-by-10 vector (16 Hz to 8 kHz octave bands)

The raw-audio method is simpler and handles all filtering/integration internally. Use the Leq method when you have measurements from a physical SPL meter or from splMeter.

When providing pre-computed measurements: The SPL meter must use Z frequency-weighting (unweighted). This applies to all noise compliance functions (NC, RNC, RC) — octave-band filtering provides the frequency selectivity, so no additional weighting should be applied. For roomNoiseCriteria Lt input, also use fast time-weighting.

Interpreting Results

NC Rating Interpretation

The NC algorithm: compute SIL (average of 500/1k/2k/4k Hz bands) → select the NC curve corresponding to that SIL value → check if any measured bands exceed that curve → if so, apply the tangency method and append the tangent frequency.

Output formats:

  • "NC-35" — SIL-based rating; no band exceeds the SIL-selected curve

  • "NC-42 (1000 Hz)" — Tangency method drove the rating; the noted band exceeds the SIL-selected NC curve. This indicates spectral imbalance at that frequency.

  • "Below NC-15" or "Above NC-70" — Outside the published curve range

The output is always an integer NC value. When the tangency-based NC exceeds the SIL-based NC by more than 3 dB, the spectrum has an imbalance. Check specImbalance.Details to see which bands deviate from the reference curve.

RC Mark II Classification — Engineering Actions
ClassificationMeaningTypical Remediation
(N) — NeutralBalanced spectrum; ~5 dB/octave slopeAcceptable. No action needed.
(H) — HissyExcessive high-frequency energyCheck diffuser throw velocities, duct lining condition, valve noise
(R) — RumblyExcessive low-frequency energyCheck fan isolation mounts, duct breakout, flexible connectors
(RV) — Rumbly-VibratorySevere low-frequency excess with vibration riskSerious concern — address structure-borne transmission paths, verify inertia base isolation

QAI (Quality Assessment Index):

  • QAI ≤ 5 dB: Acceptable spectral balance

  • QAI > 5 dB: Poor balance. The classification letter tells you which region dominates.

  • QAI = 0: Perfect match to the ideal RC contour (rare in practice)

RNC vs NC — Diagnosing Fluctuation

When RNC significantly exceeds NC for the same recording, the noise has temporal variation causing additional annoyance. The larger the difference, the more the temporal variation contributes to the overall noise problem.

Common causes of fluctuation: variable-frequency drives on fans, cycling compressors, duct resonances at low frequency, interaction between multiple HVAC units.

Speech Interference Level (SIL) Interpretation

SIL is the arithmetic average of octave-band Leq at 500, 1000, 2000, and 4000 Hz. Higher SIL values indicate greater difficulty communicating by speech. Compare against project specifications or use the STI/SII metrics for a more detailed speech intelligibility assessment.

Rattle Risk Interpretation

The rattleRisk output assesses whether low-frequency levels could excite lightweight building elements (ceiling tiles, light fixtures, ductwork panels):

  • No rattle risk: Levels are below perceptibility thresholds at 16 and 31.5 Hz

  • Moderate risk (Region B): Vibration moderately perceptible — may cause intermittent rattles

  • High risk (Region A): Vibration clearly perceptible — rattling of lightweight structures likely

Check rattleRisk.Details for the specific assessment per frequency band.

Troubleshooting

ObservationLikely CauseAction
NC seems fine but occupants complainNoise fluctuates — NC averages away the annoyanceRun roomNoiseCriteria to quantify fluctuation penalty
NC exceeds target by 1–2 dBOne band drives tangency while SIL is within targetCheck specImbalance.Details — treatment may be needed in one band only
RC shows "(RV)"Severe low-frequency excess at 16 or 31.5 HzDo not attempt to mask with absorption — isolate the vibration source
RNC errors on short recordingSurging or fluctuation detected but recording under 15 s (correction needs 150 samples)Re-record ≥15 s, or set IsSurging=false, IsFluctuating=false to bypass correction (result will not account for temporal variation)
NC/RC ratings differ significantlyThey use different band ranges (NC: 63–8kHz, RC: 16–4kHz) and methodsNormal; RC captures low-frequency problems NC misses
Measurements vary widely by positionRoom modes and proximity to sourcesReport worst-case; measure at multiple positions or sweep per measurement conditions above
Bands below 63 Hz needed but instrument can't measure themType 2 meters often roll off below 63 HzUse Type 1 meter for RC/RNC (which include 16 and 31.5 Hz bands)
Background noise contaminates measurementSource noise isn't >10 dB above ambient in all bandsMeasure with source off, verify ≥10 dB separation. Apply background correction if 3–10 dB difference.

Copyright 2026 The MathWorks, Inc.


Requirements and compatibility

Works with: Claude Code, Claude apps, OpenAI Codex, GitHub Copilot, Cursor, Gemini CLI, Kiro, OpenCode, Goose, Amp, Roo Code, JetBrains Junie, Factory Droid, Devin (ex-Windsurf), Mistral Vibe, OpenHands, Letta

“Works with” means the tool reads the open Agent Skills format; a skill written for one tool may use features others lack.

Security

No issues found by our static scan· No issues found

A static scan is not a guarantee. Skills are third-party content: review a skill before you let an agent use it.

Attribution and licence

Created by
MathWorks
Publisher
MathWorks (Official)
Source
matlab/matlab-agentic-toolkit · skills-catalog/signal-processing/matlab-evaluate-acoustic-metrics · commit 2a7f215
Licence
BSD 2-Clause License (redistribution allowed)
  • LICENSE (added by AutoGineer from LICENSE.md)
  • ATTRIBUTION.md (written by AutoGineer)
Synced

AutoGineer is not affiliated with or endorsed by MathWorks or MathWorks.

Download ZIP

The ZIP holds the skill’s files, its licence files and an ATTRIBUTION.md. Download matlab-evaluate-acoustic-metrics.zip