Generated banner for Matlab Evaluate Acoustic Metrics
Generated logo for Matlab Evaluate Acoustic Metrics

Matlab Evaluate Acoustic Metrics

MathWorksOfficialCreated by MathWorks

  • Skill
  • Tool integration
  • Science and research
  • BSD-2-Clause
  • No issues found

From the author

Select and use Audio Toolbox acoustic, psychoacoustic, and speech quality metrics. Use when computing loudness, sharpness, roughness, fluctuation strength, noise criteria (NC/RNC/RC), speech transmission index (STI), speech intelligibility index (SII), speech quality (ViSQOL, STOI), SPL, reverberation time (RT60), tone-to-noise ratio, or prominence ratio. Also use when asked about PESQ, POLQA, calibration factor, EBU R 128, LUFS, HVAC noise, background noise evaluation, or how to measure audio quality or noise compliance. Covers calibration, standard selection, signal alignment, and the complete function inventory including what does NOT exist.
— the description by MathWorks

AutoGineer summary

Written by AutoGineer from the skill’s own files, not by the author

This skill provides a structured approach to using MATLAB Audio Toolbox for acoustic measurement and analysis. It guides users through selecting the correct functions for psychoacoustic metrics, speech intelligibility, noise compliance, and broadcast loudness. The skill emphasizes proper calibration techniques, standard-compliant workflows, and the correct handling of signal data to ensure accurate results, while explicitly warning against the use of nonexistent or licensed-restricted functions.

What it does

  • Calculates psychoacoustic metrics like loudness, sharpness, roughness, and fluctuation strength.
  • Evaluates speech quality and intelligibility using metrics such as ViSQOL, STOI, STI, and SII.
  • Assesses noise compliance using NC, RC, and RNC ratings for various environments.
  • Performs offline SPL measurements and broadcast loudness checks (EBU R 128).
  • Provides guidance on microphone calibration and system-level calibration factors.
  • Offers standard-compliant filtering and unit conversion utilities.

When to use it

  • When you need to measure perceived loudness or sound quality in a research or engineering context.
  • When evaluating room acoustics or HVAC noise compliance against industry standards.
  • When analyzing speech intelligibility for communication systems or public address setups.
  • When you need to calibrate audio recordings for accurate SPL or metric computation.
  • When you need to perform broadcast loudness compliance checks.

Advantages

  • Ensures adherence to international standards like ISO 532-1/2, ANSI/ASA S12.2, and IEC 60268-16.
  • Prevents common errors such as incorrect function usage, argument ordering, or manual implementation of complex algorithms.
  • Provides clear guidance on calibration to ensure measurement accuracy.
  • Streamlines the selection of appropriate metrics based on specific application goals.

Usage examples

“How do I calculate the loudness of a recording in sones?”
The agent will guide you to use the acousticLoudness function, specifying the ISO 532-1 method, applying your calibration factor, and selecting the appropriate sound field.
“Is my office HVAC noise compliant?”
The agent will recommend using the roomCriteria function to obtain an RC rating, explaining how to interpret the output and verify the measurement conditions.
“How can I measure the speech quality of a processed audio file?”
The agent will instruct you to use the visqol function with the 'speech' mode, ensuring the processed signal is passed as the first argument.
“How do I calibrate my microphone for SPL measurements?”
The agent will explain how to use calibrateMicrophone with a 1 kHz tone recording and a known SPL reference to compute the correct calibration factor.

Install

  1. Download the skill as a ZIP:

    https://autogineer.com/agent-skills/matlab/matlab-evaluate-acoustic-metrics/download
  2. Unzip it into the cross-client skills folder of your project:

    mkdir -p .agents/skills && unzip matlab-evaluate-acoustic-metrics.zip -d .agents/skills

Documentation by MathWorks

Evaluate Acoustic Metrics

Select the correct Audio Toolbox function for acoustic measurement, apply proper calibration, and choose appropriate standards — instead of reimplementing algorithms or calling nonexistent functions.

When to Use

  • Computing psychoacoustic metrics (loudness, sharpness, roughness, fluctuation)

  • Evaluating speech quality or intelligibility (ViSQOL, STOI, STI, SII)

  • Assessing noise compliance (NC rating, RC rating, RNC, SIL)

  • Measuring SPL from recordings (offline, calibrated)

  • Computing broadcast loudness (EBU R 128 / LUFS)

  • Measuring reverberation time (RT60) from impulse responses

  • Detecting tonal content (tone-to-noise ratio, prominence ratio)

  • Converting microphone sensitivity to CalibrationFactor

  • User mentions PESQ or POLQA (redirect to correct alternatives)

When NOT to Use

  • Real-time streaming audio processing loops — use matlab-process-streaming-audio

  • Audio device I/O, recording, or live calibrateMicrophone — use matlab-play-record-audio

  • Audio plugin authoring (VST/AU) — use matlab-write-audio-plugin

  • General filter design unrelated to measurement — use matlab-design-digital-filter

  • Spatial audio / HRTF / SOFA processing

Workflow

Follow this decision tree to route the user's goal to the right function:

1. Identify the measurement goal
GoalCategoryGo to
"How loud is it?" (perceived)Psychoacoustic→ Psychoacoustic Metrics
"Does it comply with broadcast loudness?"Broadcast→ Broadcast Loudness
"Is the noise level acceptable for this space?"Noise compliance→ Noise Compliance
"Can people understand speech in this room?"Speech intelligibility→ STI/SII Measurement
"How good does processed speech sound?"Speech quality→ Speech Quality
"What's the SPL?"Level measurement→ SPL Measurement
"What's the reverberation time?"Room acoustics→ RT60
"Is there a tonal component?"Tonality→ Tonality
2. Ask before computing

Before writing code, confirm these with the user:

  • Calibration: Do they have a CalibrationFactor? Did they calibrate with calibrateMicrophone? (See Calibration section)

  • Standard: Which standard or method applies? (ISO 532-1 vs 532-2, NC vs RC vs RNC)

  • Sound field: Free field or diffuse field recording?

  • Application context: What space type? What's the concern? (Drives NC vs RC vs RNC selection)

3. Select function and apply

Use the Key Functions table and the category-specific patterns below.

Functions That Do NOT Exist

FunctionStatusUse Instead
pesqDoes NOT exist (proprietary ITU-T P.862 license)visqol(degraded, reference, fs, Mode="speech")
polqaDoes NOT exist (proprietary ITU-T P.863 license)visqol(degraded, reference, fs)

Never suggest pesq or polqa. They are not in Audio Toolbox and cannot be added due to licensing.

Key Functions

FunctionPurposeStandardAvailable From
acousticLoudnessPerceived loudness (sones)ISO 532-1/2R2020a
acousticSharpnessPerceived sharpness (acum)DIN 45692R2020a
acousticRoughnessPerceived roughness (asper)—R2021a
acousticFluctuationFluctuation strength (vacil)—R2020b
integratedLoudnessBroadcast loudness (LUFS)EBU R 128 / ITU-R BS.1770R2016b
loudnessMeterStreaming broadcast loudness meterEBU R 128 / ITU-R BS.1770R2018a
visqolFull-reference audio quality (MOS)—R2024a
stoiShort-time objective intelligibility—R2024a
mnruModulated noise reference unitITU-T P.810R2024a
dBovPower level relative to overload (dB)ITU-T G.100.1R2024a
speechTransmissionIndexSTI from IR or test signalsIEC 60268-16R2026a
speechIntelligibilityIndexSII from IR, test signals, or levelsANSI/ASA S3.5-1997R2026b
stipaExcitationGenerate STI/STIPA test signalsIEC 60268-16R2026a
siiExcitationGenerate SII test signalsANSI/ASA S3.5-1997R2026b
noiseCriteriaNC rating + SIL + spectrum imbalance + rattle riskANSI/ASA S12.2R2026b
roomNoiseCriteriaRNC rating (detects surging/fluctuations)ANSI/ASA S12.2R2026b
roomCriteriaRC Mark II rating (HVAC systems)ANSI/ASA S12.2R2026b
noiseCriteriaCurvesLook up NC curve valuesANSI/ASA S12.2R2026b
noiseCriteriaRecommendationsRecommended NC levels by room typeANSI/ASA S12.2R2026b
speechInterferenceLevelSIL from recordingANSI/ASA S12.2R2026b
rt60Reverberation time from impulse responseISO 3382-1/2R2025a
acousticToneToNoiseRatioDetect/quantify tonesECMA-418-1R2023b
acousticProminenceRatioTonality via critical band comparisonECMA-418-1R2023b
splMeterSPL measurement (time-weighted, per-band)IEC 61672R2018a
calibrateMicrophoneCompute calibration factor from known tone—R2018b
weightingFilterA/C/Z/K frequency weightingIEC 61672-1R2016b
octaveFilterSingle octave-band filterANSI S1.11-2004R2017b
octaveFilterBankMulti-band octave filteringANSI S1.11-2004R2019a

See references/function-arguments.md for complete argument lists, defaults, and valid values for each function — consult when constructing calls with non-default parameters.

Calibration

CalibrationFactor from microphone sensitivity

Convert dB sensitivity (dBV/Pa) to the linear CalibrationFactor:

sensitivity_dBV = -26;  % Example: -26 dBV/Pa microphone
calibrationFactor = 1 / 10^(sensitivity_dBV/20);

The CalibrationFactor is the 3rd positional argument for acousticLoudness, acousticSharpness, acousticRoughness, and acousticFluctuation (default: sqrt(8)). For noise compliance functions, pass it as a name-value: CalibrationFactor=value.

System-level calibration advice

Always ask the user about their signal chain. If the recording path includes a preamp, audio interface, or ADC with unknown gain, the mic sensitivity spec alone is insufficient. Recommend:

  1. Play a 1 kHz tone through the system and record it through the full signal chain (mic → preamp → ADC → WAV). Use a pistonphone for a known 94 dB reference, or place a physical SPL meter next to the microphone to get an SPL reading.

  2. Compute the system calibration factor: calibrationFactor = calibrateMicrophone(calRecording, fs, SPLreading, FrequencyWeighting="Z-weighting")

  3. Pass that factor to the measurement function

calibrateMicrophone expects a 1 kHz tone recording as input. The SPLreading argument is the known SPL in dB (e.g., 94 from a pistonphone, or the value shown on a physical SPL meter).

Cross-reference: for the physical recording workflow with calibrateMicrophone, see the matlab-play-record-audio skill.

Patterns

Psychoacoustic Metrics
[audioIn, fs] = audioread("recording.wav");
calFactor = 1 / 10^(-26/20);

loudness = acousticLoudness(audioIn, fs, calFactor, ...
    Method="ISO 532-1", SoundField="diffuse", TimeVarying=true);

sharpness = acousticSharpness(audioIn, fs, calFactor, ...
    SoundField="diffuse", TimeVarying=true);

roughness = acousticRoughness(audioIn, fs, calFactor, SoundField="diffuse");

fluctuation = acousticFluctuation(audioIn, fs, calFactor, SoundField="diffuse");

Return types: acousticLoudness returns a scalar (sones) for stationary analysis. With TimeVarying=true, it returns a column vector (time-varying loudness in sones). The second output (specificLoudness) is a matrix (time x critical bands). It does NOT return a struct or timetable.

Ask the user:

  • ISO 532-1 (Zwicker, stationary/time-varying) or ISO 532-2 (Moore-Glasberg)?

  • Free-field or diffuse-field recording?

  • Time-varying analysis needed?

See references/psychoacoustic-metrics.md for method selection guidance (ISO 532-1 vs 532-2), interpretation tables (sone values, sharpness/roughness/fluctuation scales), tonality metric selection, and combined sound quality assessment workflows.

Unit Conversions

Use built-in functions — do NOT reimplement conversion formulas manually:

ConversionFunctionMethod selection
phon → sonephon2sone(phon, standard)"ISO 532-1" (default), "ISO 532-2"
sone → phonsone2phon(sone, standard)"ISO 532-1" (default), "ISO 532-2"
Hz → ERBhz2erb(freq)Single formula (no variants)
ERB → Hzerb2hz(erb)Single formula (no variants)
Hz → barkhz2bark(freq)Single formula (no variants)
bark → Hzbark2hz(bark)Single formula (no variants)
Hz → melhz2mel(freq, MelStyle=s)"oshaughnessy" (default), "slaney"
mel → Hzmel2hz(mel, MelStyle=s)"oshaughnessy" (default), "slaney"

When the user specifies a standard (e.g., "ISO 532-2"), pass it as the second positional argument for phon2sone/sone2phon. For hz2mel/mel2hz, use the MelStyle name-value pair.

Noise Compliance

Choose the function based on the application:

SituationFunctionWhy
General background noise ratingnoiseCriteriaStandard NC curves (ANSI/ASA S12.2)
HVAC system noise specificallyroomCriteriaRC Mark II designed for HVAC evaluation
Noise with audible surging/fluctuationroomNoiseCriteriaRNC penalizes time-varying noise (requires ≥15 s recording)
Quick speech interference checkspeechInterferenceLevelDirect SIL value
Need recommended levels for room typenoiseCriteriaRecommendationsLookup table by room use
[audioIn, fs] = audioread("office_noise.wav");

[NC, SIL, specImbalance, rattleRisk] = noiseCriteria(audioIn, fs, ...
    CalibrationFactor=2.3);

[RC, LMF, QAI, rattleRisk] = roomCriteria(audioIn, fs, ...
    CalibrationFactor=2.3);

SIL = speechInterferenceLevel(audioIn, fs, CalibrationFactor=2.3);

rec = noiseCriteriaRecommendations("NC", Occupancy="all");

Return types:

  • NC is a string (e.g., "NC-35" or "NC-56 (1000 Hz)" if a band exceeds)

  • RC is a string (e.g., "RC-32(N)" — the letter indicates spectrum quality: N/R/H/RV)

  • SIL and LMF are double scalars (dB)

  • QAI is a double scalar (dB; 0 = ideal neutral)

  • specImbalance and rattleRisk are structs with .Summary (string) and .Details (table) — access .Summary for display. Exception: specImbalance degrades to a char scalar (not a struct) when NC exceeds the curve range (e.g., "Above NC-70") or falls below NC-15. Guard with isstruct(specImbalance) before dot-indexing.

  • noiseCriteriaRecommendations requires a criteria name argument: "NC", "RNC", or "RC"

Ask the user:

  • What type of space? (office, classroom, hospital, concert hall)

  • Is the noise source HVAC? → prefer roomCriteria

  • Is the noise steady or fluctuating? → if fluctuating, use roomNoiseCriteria

See references/noise-compliance.md for detailed output interpretation and selection guidance.

Speech Quality
[degraded, fs] = audioread("processed_speech.wav");
[reference, ~] = audioread("reference_speech.wav");

mosScore = visqol(degraded, reference, fs, Mode="speech");

intelligibility = stoi(degraded, reference, fs);

Critical: stoi and visqol argument order is (processed, reference, fs) — processed/degraded signal FIRST.

visqol modes: "speech" for narrowband/wideband speech (outputs 1-5 MOS), "audio" (default) for general audio.

STI/SII Measurement

Two methods are available for both speechTransmissionIndex and speechIntelligibilityIndex:

IR-based method (simpler — no alignment needed):

[ir, fs] = audioread("room_impulse_response.wav");
sti = speechTransmissionIndex(ir, fs);
sii = speechIntelligibilityIndex(ir, fs);

Direct method (from test signals transmitted through the system):

fs = 48000;
reference = stipaExcitation(fs, Duration=15);
% Transmit reference through system, record as 'processed'
[processed, ~] = audioread("received_stipa.wav");

% IMPORTANT: Align signals before computing (see Signal Alignment)
processed = alignsignals(processed, reference);

sti = speechTransmissionIndex(processed, reference, fs);

Ask the user:

  • Do they have an impulse response? → use IR method (simpler, no alignment needed)

  • Measuring live? → generate test signal, transmit, record, align, compute

  • STI or SII? STI for room/PA systems (IEC 60268-16); SII for hearing/communication (ANSI S3.5)

See references/sti-measurement.md for STI NV arguments, post-processing adjustment workflow (Annex M), test signal generation, and result interpretation. See references/sii-measurement.md for SII standard clause selection (5.1-5.3), BandImportanceFunction guidance, measurement positioning, and result interpretation.

SPL Measurement (Offline)
[audioIn, fs] = audioread("recording.wav");

spl = splMeter(SampleRate=fs, ...
    Bandwidth="Full band", ...
    FrequencyWeighting="A-weighting", ...
    TimeWeighting="fast", ...
    CalibrationFactor=2.3);

[Lt, Leq, Lpeak, Lmax] = spl(audioIn);

% For a single overall value, read the final row
fprintf("Leq: %.1f dB(A)\n", Leq(end));

Valid Bandwidth values: "Full band" (overall level), "1 octave", "2/3 octave", "1/3 octave". There is no "broadband" option — use "Full band" for a single overall SPL value.

Output arity: All outputs (Lt, Leq, Lpeak, Lmax) have one row per input sample. For a 12-second file at 44.1 kHz, that is 539,648 rows. Never fprintf or disp the full output — it will hang. Instead:

  • Single overall value: read Leq(end) (the final accumulated value)

  • Time-interval readings: downsample to interval boundaries: Leq(round(fs*T):round(fs*T):end, :) where T is the desired interval in seconds

TimeInterval controls the integration window for Leq computation but does NOT reduce the number of output rows.

Do not manually compute 20*log10(rms(audioIn)/20e-6) — splMeter handles calibration, weighting, and time integration correctly per IEC 61672.

Multi-band (octave-band) SPL: Use splMeter with Bandwidth="1 octave" — do NOT use octaveFilterBank + manual dB conversion. Key properties for octave-band SPL:

[audioIn, fs] = audioread("recording.wav");

spl = splMeter(SampleRate=fs, ...
    Bandwidth="1 octave", ...
    FrequencyWeighting="Z-weighting", ...
    TimeWeighting="fast", ...
    FrequencyRange=[15 8000], ...
    OctaveFilterOrder=8, ...
    CalibrationFactor=2.3);

[Lt, Leq, Lpeak, Lmax] = spl(audioIn);
cf = getCenterFrequencies(spl);

Critical gotchas for octave-band splMeter:

  • Property name is OctaveFilterOrder (not FilterOrder). FilterOrder does not exist on splMeter.

  • FrequencyRange compares against true center frequencies (fc = 1000 × 10^(3b/10) per IEC 61260), not nominal values. A band is included only if its true center falls within [lower, upper]. Bands below 1 kHz have true centers slightly above nominal (e.g., "63 Hz" = 63.10); bands above 1 kHz have true centers below nominal (e.g., "2 kHz" = 1995.26, "8 kHz" = 7943.28). Use floor(true_center) for lower bounds and ceil(true_center) for upper bounds. Common case "16 Hz to 8 kHz": use [15 8000] — the 16 Hz true center is 15.85 (so 15 ≤ 15.85 includes it) and 8 kHz true center is 7943 (so 8000 ≥ 7943 includes it). Do NOT use [16 8000] — this drops the 16 Hz band.

  • Output is per-sample (see Output arity note above). Never print the full output. For time-interval readings, downsample: Lt100ms = Lt(round(fs*0.1):round(fs*0.1):end, :);

See references/spl-measurement.md for weighting selection guidance (A/C/Z and fast/slow), SPL interpretation tables, occupational exposure limits, splMeter vs poctave equivalency, and common measurement scenarios.

Broadcast Loudness (EBU R 128)
[audioIn, fs] = audioread("broadcast_content.wav");
[loudness, loudnessRange] = integratedLoudness(audioIn, fs);

% Check compliance: target is -23 LUFS +/- 1 LU
isCompliant = abs(loudness - (-23)) <= 1;

Use integratedLoudness for offline compliance checks. Use loudnessMeter for streaming/real-time monitoring (see matlab-process-streaming-audio).

RT60
[ir, fs] = audioread("room_ir.wav");
rtsummary = rt60(ir, fs, Bandwidth="1 octave");

Ask the user:

  • What is the room type? (drives the target RT60)

  • Do they have an IR, or do they need to measure one?

  • T30 (standard) vs T20 (when noise floor limits dynamic range)?

See references/rt60-measurement.md for target RT60 values by space type, T20/T30/EDT interpretation, frequency-dependent analysis, and relationship to STI.

Tonality
[audioIn, fs] = audioread("machine_noise.wav");

[tnr, tnrFreq, isProminent] = acousticToneToNoiseRatio(audioIn, fs);

[pr, prFreq, isProminent] = acousticProminenceRatio(audioIn, fs);

All outputs are empty (0×1) when no tonal components are detected. Check isempty(tnr) before indexing.

Standards-Compliant Filters (Custom Preprocessing)

The metric functions above perform standards-compliant filtering internally. Use standalone filter objects only for custom measurement workflows where no single metric function applies AND you do not need SPL output:

% A-weighting filter
wf = weightingFilter("A-weighting", fs);
weightedSignal = wf(audioIn);

% Octave-band filter bank (for waveform-level band decomposition only)
ofb = octaveFilterBank("1 octave", fs, ...
    FrequencyRange=[31.5 16000], FilterOrder=8);
bandSignals = ofb(audioIn);

If you need octave-band SPL levels, use splMeter with Bandwidth="1 octave" instead of octaveFilterBank + manual dB conversion. See the Multi-band SPL section above.

Signal Alignment

FunctionInternal alignment?Action
visqolYesNo action needed
stoiNoAlign before calling
speechTransmissionIndexNoAlign for direct method; IR method avoids issue
speechIntelligibilityIndexNoAlign for direct method; IR method avoids issue

For the direct (processed, reference, fs) method, always align signals:

processed = alignsignals(processed, reference);

SII is more sensitive to misalignment than STI. At 50 ms delay: SII error ~0.016, STI negligible. At 200 ms: SII ~0.036, STI ~0.017. The IR-based (ir, fs) method avoids alignment issues entirely.

Common Mistakes

MistakeWhy it failsCorrect approach
Call pesq(reference, degraded, fs)Function does not existvisqol(degraded, reference, fs, Mode="speech")
stoi(reference, processed, fs)Wrong argument orderstoi(processed, reference, fs) — processed FIRST
acousticFluctuationStrength(...)Wrong function nameacousticFluctuation(audioIn, fs, calFactor)
Implement NC from scratch with hardcoded curvesMisses SIL, spectrum imbalance, rattle risknoiseCriteria(audioIn, fs, CalibrationFactor=cf)
20*log10(rms(x)/20e-6) for SPLNo weighting, no time integration, no calibrationsplMeter with appropriate settings
Implement STI algorithm manually~100 lines, error-prone, misses NV optionsspeechTransmissionIndex(ir, fs)
Divide signal by calibration factor manuallyIncorrect; factor is a multiplier, not a divisorPass as positional arg or CalibrationFactor=value
Skip alignment for direct STI/SIISilent accuracy degradationalignsignals(processed, reference) before calling
Use acousticLoudness for broadcast loudnessWrong standard (ISO 532 = sones, not LUFS)integratedLoudness for EBU R 128 compliance
string(rattleRisk) or fprintf("%s", specImbalance)These are structs, not stringsAccess .Summary field: rattleRisk.Summary
specImbalance.Summary when NC is out of curve rangespecImbalance degrades to char (not struct) when "Above NC-70" or below NC-15Guard: if isstruct(specImbalance), disp(specImbalance.Summary); end
roomNoiseCriteria on recordings shorter than 15 sANSI/ASA S12.2-2019 requires ≥150 Lt samples at 100 ms intervalsEnsure recording is at least 15 seconds; use noiseCriteria for shorter clips
round(NC) or arithmetic on NC/RC outputNC and RC are strings, not numbersUse directly: fprintf("%s\n", NC)
noiseCriteriaRecommendations() with no argsFirst argument (criteria name) is requirednoiseCriteriaRecommendations("NC")
loudness.OverallLoudness after acousticLoudnessReturns a scalar or vector, not a structUse directly: fprintf("%.1f sones\n", loudness)
splMeter(..., FilterOrder=8)Property does not exist on splMeterUse OctaveFilterOrder=8
splMeter(..., FrequencyRange=[16 8000]) for 16 Hz–8 kHzDrops 16 Hz band (true center is 15.85 Hz, which is below 16)Use FrequencyRange=[15 8000] — use floor(true_center) for lower bound
octaveFilterBank + 20*log10(rms(band)/pRef) for SPLManual, no time weighting, no calibration integrationUse splMeter with Bandwidth="1 octave"
Treating splMeter output as a single valueAll outputs have one row per input sample (e.g., 539k rows for 12s at 44.1 kHz)Use Leq(end) for a single value, or downsample to interval boundaries

Conventions

  • Always ask about the user's measurement goal before selecting a function

  • Always ask about calibration — recommend calibrateMicrophone for system-level accuracy

  • Default to SoundField="free" for anechoic/outdoor, "diffuse" for reverberant rooms

  • Default to Method="ISO 532-1" for loudness (Zwicker method, most common)

  • Use IR-based methods for STI/SII when an impulse response is available (avoids alignment)

  • Pass CalibrationFactor explicitly rather than pre-scaling the signal

  • For noise compliance, prefer roomCriteria for HVAC and noiseCriteria for general background noise


Copyright 2026 The MathWorks, Inc.


Files

ATTRIBUTION.md

Attribution

This folder is an unmodified copy of the Agent Skill "matlab-evaluate-acoustic-metrics", distributed by AutoGineer (https://autogineer.com/agent-skills).

The skill's own files are unmodified copies. AutoGineer is not affiliated with or endorsed by the author or the publisher.

Files added by AutoGineer

  • ATTRIBUTION.md: this file, written by AutoGineer

  • LICENSE: copied from LICENSE.md

Requirements and compatibility

Works with: Claude Code, Claude apps, OpenAI Codex, GitHub Copilot, Cursor, Gemini CLI, Kiro, OpenCode, Goose, Amp, Roo Code, JetBrains Junie, Factory Droid, Devin (ex-Windsurf), Mistral Vibe, OpenHands, Letta

“Works with” means the tool reads the open Agent Skills format; a skill written for one tool may use features others lack.

Security

No issues found by our static scan· No issues found

A static scan is not a guarantee. Skills are third-party content: review a skill before you let an agent use it.

Attribution and licence

Created by
MathWorks
Publisher
MathWorks (Official)
Source
matlab/matlab-agentic-toolkit · skills-catalog/signal-processing/matlab-evaluate-acoustic-metrics · commit 2a7f215
Licence
BSD 2-Clause License (redistribution allowed)
  • LICENSE (added by AutoGineer from LICENSE.md)
  • ATTRIBUTION.md (written by AutoGineer)
Synced

AutoGineer is not affiliated with or endorsed by MathWorks or MathWorks.

Download ZIP

The ZIP holds the skill’s files, its licence files and an ATTRIBUTION.md. Download matlab-evaluate-acoustic-metrics.zip