From the author

Diagnose and remediate per-node issues on a HyperPod cluster (EKS or Slurm) — a specific node is unhealthy, unresponsive, stuck, or needs replacing. Covers on-node EFA, GPU / accelerator hardware (XID, ECC, NVLink, row-remap, DCGM), Slurm node down/drained, disk and memory pressure, per-node lifecycle-script failures, SSM agent, container runtime, kernel panics, pod networking. Read-only. Not for cluster-wide provisioning (→ hyperpod-cluster-debugger), NCCL (→ hyperpod-nccl), or MFU (→ hyperpod-mfu-debugger).
— the description by AWS Labs

AutoGineer summary

Written by AutoGineer from the skill’s own files, not by the author

The HyperPod Node Debugger provides a structured, read-only diagnostic workflow for identifying and resolving issues on individual nodes within a HyperPod cluster. It covers a wide range of failure modes, including EFA networking, GPU/accelerator hardware faults (XID, ECC, NVLink), Slurm node states, resource exhaustion, and container runtime errors. The skill emphasizes a safe, non-destructive triage process, requiring explicit customer approval for any remediation steps, and includes specific guidance for Infrastructure-as-Code (IaC) environments to prevent configuration drift.

What it does

  • Performs read-only triage of cluster nodes to identify health failures.
  • Maps detected symptoms to specific diagnostic sections for targeted troubleshooting.
  • Provides verified commands for remediation, including rebooting or replacing nodes.
  • Includes safety checks for IaC-managed resources to prevent configuration drift.
  • Supports both EKS and Slurm orchestrators for HyperPod environments.
  • Guides the user through a structured investigate-reboot-replace escalation path.

When to use it

  • When a specific node in a HyperPod cluster is unhealthy, unresponsive, or stuck.
  • When training jobs hang due to suspected hardware or networking issues on a single node.
  • When GPU/accelerator errors (e.g., XID, ECC, NVLink) are suspected.
  • When investigating node-level resource exhaustion (disk, memory, OOM).
  • When Slurm nodes are marked as down or drained unexpectedly.

Advantages

  • Standardizes the diagnostic process for complex HyperPod node failures.
  • Reduces manual effort by automating the collection of cluster and node health signals.
  • Prioritizes safety by enforcing a read-only triage phase before any remediation.
  • Provides clear guidance on when to escalate to AWS Support.
  • Integrates with existing IaC workflows to maintain infrastructure integrity.

Usage examples

“My node i-0123456789abcdef0 is stuck in a Pending state. How do I check it?”
The agent will run the triage script focused on that specific instance ID, identify the failure reason (e.g., lifecycle script or hardware), and provide the corresponding diagnostic steps.
“I suspect a GPU hardware failure on node i-0987654321fedcba0. What should I do?”
The agent will guide you to check for XID or ECC errors using the provided diagnostic commands and, if confirmed, suggest the appropriate batch-reboot or batch-replace procedure.

Install

  1. Download the skill as a ZIP:

    https://autogineer.com/agent-skills/awslabs/hyperpod-node-debugger/download
  2. Unzip it into the cross-client skills folder of your project:

    mkdir -p .agents/skills && unzip hyperpod-node-debugger.zip -d .agents/skills

Documentation by AWS Labs

HyperPod Node Debugger

Operating policy. Run read-only diagnostics yourself. Never run a command that changes cluster, node, or workload state — present each one as a Suggested command (run this yourself) block and wait for the customer. Destructive order: investigate → reboot → replace (replace destroys root + secondary volumes; not supported on Slurm controller nodes). Never discard training state, logs, or caches on speculation.

IaC note (always include with mutation commands). When you suggest any command that changes cluster, VPC, SG, subnet, or EKS configuration (e.g. authorize-security-group-*, modify-vpc-attribute, update-cluster, kubectl label/cordon/drain, create namespace, set env daemonset), ask the customer first whether the cluster / VPC / SG is managed by Infrastructure-as-Code (CloudFormation, CDK, Terraform, Pulumi). If yes, tell them: "Apply this change in your IaC source first, then deploy through the pipeline — running the command directly will drift from your template and the next stack update may overwrite it." If they need to fix the issue immediately and the IaC change will follow, flag the drift explicitly so they remember to reconcile.

Read-only triage. scripts/triage-cluster.sh (and helpers check-efa-sg.sh, check-node-reachability.sh, check-vpc-config.sh) read state and print each issue as [FAIL] ... → references/node-diagnostics-detail.md § <section>. Catalog of customer-ticket patterns: references/node-issue-catalog.md.


Workflow

  1. Collect cluster name, region, suspect instance ID, exact error string from logs.

  2. Run scripts/triage-cluster.sh (add --node <INSTANCE-ID> to focus one node).

  3. For every [FAIL] / issue entry, Read the referenced section.

  4. Present: what script detected (copy the line verbatim), root cause, exact command(s) with instance/SG IDs filled in, blast radius (e.g. "reboots i-xxx", "wipes volumes on replacement"). For any command that mutates cluster/VPC/SG/EKS state, ask whether the affected resource is IaC-managed and surface the drift warning from the operating-policy note above.

  5. Wait for explicit customer approval. Destructive order: investigate → reboot → replace.

  6. Re-run triage to confirm. Iterate if not cleared.

Step 1: Triage

bash scripts/triage-cluster.sh --cluster <CLUSTER_NAME_OR_ARN> --region <REGION>

# Focus on one node:
bash scripts/triage-cluster.sh --cluster <CLUSTER_NAME_OR_ARN> --region <REGION> --node <INSTANCE_ID>

One pass collects: cluster status + NodeRecovery, events, per-node health (HyperPod + EKS labels, Slurm states), VPC/SG snapshot, CloudWatch availability, SSM readiness, on-node resource checks (disk, memory, /dev/shm, OOM, NVMe, time sync, SSM agent), Slurm node→instance mapping.

Tags: [PASS] passed · [FAIL] issue with a → references/... pointer · [WARN] advisory · [INFO] informational. Priorities: P0 blocks operation · P1 degraded · P2 informational.

Step 2: Match signal → section

Events (list-cluster-events) — provisioning-time:

EventSection
"EFA health checks did not run successfully" (public-doc verbatim signal)A: EFA/SG
Instance bootstrap or network-misconfiguration eventA + B: VPC
Lifecycle-script failure or timeoutD: Lifecycle
Insufficient-capacity or AZ-mismatch failure at creationC: Capacity
Hardware failure / UnschedulablePendingReplacementF: Hardware

EKS labels:

LabelSection
node-health-status: UnschedulablePendingReplacementF
node-health-status: UnschedulablePendingRebootF
deep-health-check-status: FailedG → F

Symptoms:

SymptomSection
Training hangs at NCCL init / AllReduceA → E
Slurm node down / "Node unexpectedly rebooted"H: Slurm
Jobs stuck PENDING / COMPLETINGH
Auto-repair not triggeringF
GPU not visible / XID / ECC errorsG
GPU row-remap pending/failed / silent NaNs / DCGM FailG § G.1.a/b
Disk full / OOM / "Cannot allocate memory"I: Resources
Wrong vCPU count (e.g. 96 instead of 192 on p5.48xlarge)J: Config
Container CrashLoopBackOff / runtime crashM: Container Runtime
aws-node CrashLoopBackOff / gRPC 50051 refusedO: CNI / Pod Networking
Pods stuck Pending with no IP / CNI errorO
DNS resolution / enableDnsSupportB § B.2
Public subnet / IGW misconfiguredB § B.3
Missing VPC endpoints (ECR / STS / FSx)B § B.4
EKS VPC / SG mismatch with HyperPodB § B.5
Kernel panic / watchdog / hung taskN: Kernel
Need shell on a nodeK: SSM
Collect logs for AWS SupportL: Log Collection

A: EFA / Security Group

Per the HyperPod prerequisites doc, the SG must allow all inbound and outbound to itself. scripts/check-efa-sg.sh validates self-ref rules on every cluster SG. On-node EFA check via scripts/check-node-reachability.sh over SSM. Full: § A.

B: VPC / Routing

SG/subnet VPC mismatch, missing S3 Gateway endpoint, EKS auth mode, worker→controller routing, VPC DNS support, private-subnet + NAT / VPC endpoints, EKS↔HyperPod VPC alignment. scripts/check-vpc-config.sh. Full: § B.

C: Capacity / AZ

Insufficient-capacity failure at creation, or no subnets in the AZ where capacity is available. Check AZ offerings via describe-instance-type-offerings, then change subnet AZ or use Flexible Training Plans / ODCR. Full: § C.

D: Lifecycle Scripts

Surfaced in cluster events + CloudWatch under LifecycleConfig/<group>/<instance-id>. Common: S3 connectivity, IAM gaps, CRLF line endings, infinite loops, parameter-name mismatch. Full: § D.

E: Software Versions

Delegate to hyperpod-version-checker to compare NVIDIA driver, CUDA, NCCL, EFA installer, OFI NCCL, PyTorch across nodes. Ensure job env has FI_PROVIDER=efa, FI_EFA_USE_DEVICE_RDMA=1, NCCL_SOCKET_IFNAME=^lo,docker. Full: § E.

F: Hardware / Auto-Repair

Confirm NodeRecovery=Automatic, inspect the EKS health labels + sagemaker.amazonaws.com/fault-details annotation, and read the SagemakerHealthMonitoringAgent/<group>/<instance> CloudWatch stream. HMA runs passive background checks on GPU and Neuron state and reboots the node on count mismatch (per the HMA doc: "if there's a mismatch between the expected number of GPUs … and the count returned by nvidia-smi, then HMA reboots the node"; same for neuron-ls). Manual recovery order: reboot first, replace only if reboot fails; the preferred path is the batch APIs (BatchReboot/BatchReplaceClusterNodes). Full: § F · patterns: node-issue-catalog.md.

G: GPU / Accelerator

NVIDIA (p4d/p5/g5/g6): nvidia-smi + dmesg over SSM for Xid, ECC, thermal throttling. Xid classification per NVIDIA's catalog: 13 Graphics Engine Exception (application-level), 31 GPU memory page fault (application, can be driver/HW), 63 GPU memory remapping event (HW/ECC), 71 CE4 Error (HW copy engine), 74 NVLink Error (HW), 79 GPU has fallen off the bus (PCIe bus), 109 Context Switch Timeout Error (HW). Any uncorrectable ECC → drain and replace. Row-remap state is the authoritative silent-degradation signal (§ G.1.a).

Trainium / Inferentia (trn1/trn2/inf2): Neuron SDK — neuron-ls, neuron-top, neuron-monitor. nvidia-smi does not apply.

GPU / accelerator failures flow into § F for reboot / replace. Full: § G.

H: Slurm Node Management

Node down/unresponsive, unexpected reboots, stuck PENDING/COMPLETING jobs, Slurm-to-instance-ID translation. Primary access is SSM; diagnose slurmd first, fix the root cause, then start/resume the node per § H. Full: § H.

I: Resource Exhaustion

Disk full (HyperPod root volume defaults to 100 GB and is not intended to grow post-creation), OOM, os.fork() memory error, /dev/shm exhaustion, inode exhaustion. Fork-memory fix: export FI_EFA_USE_HUGE_PAGE=0. Redirect bulk data to /opt/sagemaker (secondary EBS) or /opt/dlami/nvme (instance store). Full: § I.

J: Configuration

p5.48xlarge reports 96 vCPU instead of 192 → set ThreadsPerCore=2 via update-cluster. Full: § J.

K: Node Access via SSM

No direct SSH on HyperPod. Target format sagemaker-cluster:<CLUSTER_ID>_<GROUP>-<INSTANCE_ID>. Failures: plugin missing, wrong prefix, IAM, VPC endpoints. Full: § K.

L: Log Collection

Delegate to hyperpod-issue-report for S3-stored bundles. Key CloudWatch streams: LifecycleConfig/<group>/<instance-id>, SagemakerHealthMonitoringAgent/<group>/<instance-id>. Full: § L.

M: Container Runtime

CrashLoopBackOff, OOMKilled, ImagePullBackOff, RunContainerError on EKS. kubectl describe pod + on-node crictl ps -a, journalctl -u containerd. Full: § M.

N: Kernel & System

Kernel panic, watchdog timeout, soft lockup, unexpected reboots not explained by HyperPod health monitoring. dmesg | grep -iE 'panic|watchdog|hung_task|NMI' + journalctl -b -1. nvrm-related signatures point at NVIDIA driver crashes. Full: § N.

O: CNI / Pod Networking

VPC CNI (aws-node) failures, IPAMD errors, gRPC 127.0.0.1:50051 refused, pods stuck Pending with FailedCreatePodSandBox. Script auto-checks aws-node, kube-proxy, CoreDNS. Full: § O.


Prerequisites

  • aws CLI v2, recent enough to support the HyperPod cluster commands (describe-cluster, list-cluster-nodes, batch-reboot-cluster-nodes, batch-replace-cluster-nodes)

  • python3, bash 4+ (associative arrays are required by the scripts)

  • kubectl authenticated to the EKS cluster (K8s checks skipped if absent)

  • session-manager-plugin for on-node hardware checks

  • unbuffer (from the expect package) — optional; if missing, SSM on-node probes are skipped while the rest of the triage still runs. Install via yum install expect / apt install expect.

Defaults

  • Region — required: pass --region or set $AWS_DEFAULT_REGION.

  • Target scope — all nodes; --node <ID> focuses one.

  • Event window — up to 500 most recent events (5 × 100, paginated).

  • Node list cap — up to 20,000 nodes (200 × 100); warns on cap.

  • SSM probes — 180 s per node with retry-on-throttle.

  • Colors — auto-disabled on non-TTY; --no-color to force off.

Error handling

FailureScriptTell the customer
aws sts get-caller-identity failsExit 1"Fix AWS credentials and rerun."
describe-cluster failsExit 1 after listing region's clusters"Confirm cluster name and region."
sagemaker:* / ec2:* / logs:* AccessDeniedWarn, add Missing IAM permission for <API>, continue"Grant the listed IAM action and rerun."
kubectl absent or unauthenticatedSkip K8s checks"Install/authenticate kubectl (see § K)."
session-manager-plugin absentSkip on-node probes"Install session-manager-plugin (see § K)."
SSM start-session fails or times out (180s)Mark node unreachable with → § K pointer"Rerun with --node <ID> to isolate; verify SSM agent on the node."
Cluster > 20,000 nodesFirst 20,000 paginated; warn"Use --node to target specific nodes."

Exit codes: 0 triage complete · 1 cluster not found or fatal prerequisite missing.

IAM permissions

Read-only diagnostic — covers triage-cluster.sh, check-efa-sg.sh, check-vpc-config.sh, and check-node-reachability.sh:

{
  "Action": [
    "sagemaker:DescribeCluster",
    "sagemaker:DescribeClusterNode",
    "sagemaker:ListClusterNodes",
    "sagemaker:ListClusterEvents",
    "sagemaker:ListClusters",
    "eks:DescribeCluster",
    "ec2:DescribeSecurityGroups",
    "ec2:DescribeSubnets",
    "ec2:DescribeVpcs",
    "ec2:DescribeVpcAttribute",
    "ec2:DescribeVpcEndpoints",
    "ec2:DescribeRouteTables",
    "ec2:DescribeNetworkInterfaces",
    "ec2:DescribeInstances",
    "ec2:DescribeInstanceTypeOfferings",
    "ec2:DescribeInstanceTypes",
    "logs:DescribeLogGroups",
    "logs:DescribeLogStreams",
    "logs:FilterLogEvents",
    "ssm:StartSession",
    "ssm:TerminateSession",
    "service-quotas:GetServiceQuota"
  ]
}

sts:GetCallerIdentity is implicit — it requires no IAM action. SSM on HyperPod uses start-session against sagemaker-cluster:<cluster-id>_<group>-<iid> targets — not send-command against bare instance IDs. For remediation commands, grant the matching write permission (e.g. ec2:AuthorizeSecurityGroupIngress / Egress, ec2:RevokeSecurityGroupIngress / Egress, ec2:ModifyVpcAttribute, sagemaker:UpdateCluster, sagemaker:BatchRebootClusterNodes, sagemaker:BatchReplaceClusterNodes). Not needed for the diagnostic itself.

Skill delegation

NeedUse
Cluster creation / deployment failureshyperpod-cluster-debugger (§ A / B / C / H + --validate)
Cluster-wide SSM outagehyperpod-cluster-debugger § F
Single-node SSM failurestay here — § K
Cluster-wide EFA health-check failure at creation timehyperpod-cluster-debugger § A
Single-node EFA failure post-provisioningstay here — § A
NCCL AllReduce / collective-op timeouts (distributed)hyperpod-nccl
Silent GPU NaNs on a specific node (row-remap / DCGM)stay here — § G.1 (even if discovered by NCCL)
Post-deployment cluster-wide managementhyperpod-cluster-debugger
Shell / commands on nodeshyperpod-ssm
CUDA / NCCL / EFA version comparisonhyperpod-version-checker
Diagnostic bundle for AWS Supporthyperpod-issue-report
Training performance / MFU degradationhyperpod-mfu-debugger

Escalate to AWS Support

Escalate when:

  1. SG rules correct and reachability passes but EFA still fails.

  2. VPC correct but K8s bootstrap fails — check VPC flow logs for REJECT.

  3. Hardware failure where replacement keeps failing (bad physical host).

  4. Node replacement fails with an insufficient-capacity signal despite a valid ODCR.

Before opening the case
# 1. Cluster identity + affected node status
aws sagemaker describe-cluster --cluster-name <CLUSTER> --region <REGION>
aws sagemaker list-cluster-nodes --cluster-name <CLUSTER> --region <REGION> \
  --query "ClusterNodeSummaries[?InstanceId=='<INSTANCE_ID>']"

# 2. Triage bundle (scoped to the affected node where possible)
bash scripts/triage-cluster.sh --cluster <CLUSTER> --region <REGION> --node <INSTANCE_ID> > triage.txt

# 3. Per-node log/config bundle to S3 (delegates to hyperpod-issue-report)
#    See skills/hyperpod-issue-report/SKILL.md for the exact invocation.
Include in the case
  • Cluster name + ARN and AWS region

  • Orchestrator (EKS or Slurm)

  • Affected instance IDs / node names / instance-group names

  • Timestamp window (UTC start / end) of the failure

  • Exact error strings observed (copy verbatim from pod logs, CloudWatch, dmesg, events)

  • XID numbers / ECC counts / DCGM output where hardware is implicated

  • triage.txt from step 2 above

  • S3 URI of the hyperpod-issue-report bundle from step 3

Patterns from real customer tickets: node-issue-catalog.md.

Files

LICENSE


                                 Apache License
                           Version 2.0, January 2004
                        http://www.apache.org/licenses/

   TERMS AND CONDITIONS FOR USE, REPRODUCTION, AND DISTRIBUTION

   1. Definitions.

      "License" shall mean the terms and conditions for use, reproduction,
      and distribution as defined by Sections 1 through 9 of this document.

      "Licensor" shall mean the copyright owner or entity authorized by
      the copyright owner that is granting the License.

      "Legal Entity" shall mean the union of the acting entity and all
      other entities that control, are controlled by, or are under common
      control with that entity. For the purposes of this definition,
      "control" means (i) the power, direct or indirect, to cause the
      direction or management of such entity, whether by contract or
      otherwise, or (ii) ownership of fifty percent (50%) or more of the
      outstanding shares, or (iii) beneficial ownership of such entity.

      "You" (or "Your") shall mean an individual or Legal Entity
      exercising permissions granted by this License.

      "Source" form shall mean the preferred form for making modifications,
      including but not limited to software source code, documentation
      source, and configuration files.

      "Object" form shall mean any form resulting from mechanical
      transformation or translation of a Source form, including but
      not limited to compiled object code, generated documentation,
      and conversions to other media types.

      "Work" shall mean the work of authorship, whether in Source or
      Object form, made available under the License, as indicated by a
      copyright notice that is included in or attached to the work
      (an example is provided in the Appendix below).

      "Derivative Works" shall mean any work, whether in Source or Object
      form, that is based on (or derived from) the Work and for which the
      editorial revisions, annotations, elaborations, or other modifications
      represent, as a whole, an original work of authorship. For the purposes
      of this License, Derivative Works shall not include works that remain
      separable from, or merely link (or bind by name) to the interfaces of,
      the Work and Derivative Works thereof.

      "Contribution" shall mean any work of authorship, including
      the original version of the Work and any modifications or additions
      to that Work or Derivative Works thereof, that is intentionally
      submitted to Licensor for inclusion in the Work by the copyright owner
      or by an individual or Legal Entity authorized to submit on behalf of
      the copyright owner. For the purposes of this definition, "submitted"
      means any form of electronic, verbal, or written communication sent
      to the Licensor or its representatives, including but not limited to
      communication on electronic mailing lists, source code control systems,
      and issue tracking systems that are managed by, or on behalf of, the
      Licensor for the purpose of discussing and improving the Work, but
      excluding communication that is conspicuously marked or otherwise
      designated in writing by the copyright owner as "Not a Contribution."

      "Contributor" shall mean Licensor and any individual or Legal Entity
      on behalf of whom a Contribution has been received by Licensor and
      subsequently incorporated within the Work.

   2. Grant of Copyright License. Subject to the terms and conditions of
      this License, each Contributor hereby grants to You a perpetual,
      worldwide, non-exclusive, no-charge, royalty-free, irrevocable
      copyright license to reproduce, prepare Derivative Works of,
      publicly display, publicly perform, sublicense, and distribute the
      Work and such Derivative Works in Source or Object form.

   3. Grant of Patent License. Subject to the terms and conditions of
      this License, each Contributor hereby grants to You a perpetual,
      worldwide, non-exclusive, no-charge, royalty-free, irrevocable
      (except as stated in this section) patent license to make, have made,
      use, offer to sell, sell, import, and otherwise transfer the Work,
      where such license applies only to those patent claims licensable
      by such Contributor that are necessarily infringed by their
      Contribution(s) alone or by combination of their Contribution(s)
      with the Work to which such Contribution(s) was submitted. If You
      institute patent litigation against any entity (including a
      cross-claim or counterclaim in a lawsuit) alleging that the Work
      or a Contribution incorporated within the Work constitutes direct
      or contributory patent infringement, then any patent licenses
      granted to You under this License for that Work shall terminate
      as of the date such litigation is filed.

   4. Redistribution. You may reproduce and distribute copies of the
      Work or Derivative Works thereof in any medium, with or without
      modifications, and in Source or Object form, provided that You
      meet the following conditions:

      (a) You must give any other recipients of the Work or
          Derivative Works a copy of this License; and

      (b) You must cause any modified files to carry prominent notices
          stating that You changed the files; and

      (c) You must retain, in the Source form of any Derivative Works
          that You distribute, all copyright, patent, trademark, and
          attribution notices from the Source form of the Work,
          excluding those notices that do not pertain to any part of
          the Derivative Works; and

      (d) If the Work includes a "NOTICE" text file as part of its
          distribution, then any Derivative Works that You distribute must
          include a readable copy of the attribution notices contained
          within such NOTICE file, excluding those notices that do not
          pertain to any part of the Derivative Works, in at least one
          of the following places: within a NOTICE text file distributed
          as part of the Derivative Works; within the Source form or
          documentation, if provided along with the Derivative Works; or,
          within a display generated by the Derivative Works, if and
          wherever such third-party notices normally appear. The contents
          of the NOTICE file are for informational purposes only and
          do not modify the License. You may add Your own attribution
          notices within Derivative Works that You distribute, alongside
          or as an addendum to the NOTICE text from the Work, provided
          that such additional attribution notices cannot be construed
          as modifying the License.

      You may add Your own copyright statement to Your modifications and
      may provide additional or different license terms and conditions
      for use, reproduction, or distribution of Your modifications, or
      for any such Derivative Works as a whole, provided Your use,
      reproduction, and distribution of the Work otherwise complies with
      the conditions stated in this License.

   5. Submission of Contributions. Unless You explicitly state otherwise,
      any Contribution intentionally submitted for inclusion in the Work
      by You to the Licensor shall be under the terms and conditions of
      this License, without any additional terms or conditions.
      Notwithstanding the above, nothing herein shall supersede or modify
      the terms of any separate license agreement you may have executed
      with Licensor regarding such Contributions.

   6. Trademarks. This License does not grant permission to use the trade
      names, trademarks, service marks, or product names of the Licensor,
      except as required for reasonable and customary use in describing the
      origin of the Work and reproducing the content of the NOTICE file.

   7. Disclaimer of Warranty. Unless required by applicable law or
      agreed to in writing, Licensor provides the Work (and each
      Contributor provides its Contributions) on an "AS IS" BASIS,
      WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or
      implied, including, without limitation, any warranties or conditions
      of TITLE, NON-INFRINGEMENT, MERCHANTABILITY, or FITNESS FOR A
      PARTICULAR PURPOSE. You are solely responsible for determining the
      appropriateness of using or redistributing the Work and assume any
      risks associated with Your exercise of permissions under this License.

   8. Limitation of Liability. In no event and under no legal theory,
      whether in tort (including negligence), contract, or otherwise,
      unless required by applicable law (such as deliberate and grossly
      negligent acts) or agreed to in writing, shall any Contributor be
      liable to You for damages, including any direct, indirect, special,
      incidental, or consequential damages of any character arising as a
      result of this License or out of the use or inability to use the
      Work (including but not limited to damages for loss of goodwill,
      work stoppage, computer failure or malfunction, or any and all
      other commercial damages or losses), even if such Contributor
      has been advised of the possibility of such damages.

   9. Accepting Warranty or Additional Liability. While redistributing
      the Work or Derivative Works thereof, You may choose to offer,
      and charge a fee for, acceptance of support, warranty, indemnity,
      or other liability obligations and/or rights consistent with this
      License. However, in accepting such obligations, You may act only
      on Your own behalf and on Your sole responsibility, not on behalf
      of any other Contributor, and only if You agree to indemnify,
      defend, and hold each Contributor harmless for any liability
      incurred by, or claims asserted against, such Contributor by reason
      of your accepting any such warranty or additional liability.

Requirements and compatibility

Works with: Claude Code, Claude apps, OpenAI Codex, GitHub Copilot, Cursor, Gemini CLI, Kiro, OpenCode, Goose, Amp, Roo Code, JetBrains Junie, Factory Droid, Devin (ex-Windsurf), Mistral Vibe, OpenHands, Letta

“Works with” means the tool reads the open Agent Skills format; a skill written for one tool may use features others lack.

Needs: Needs a command-line tool, Needs Python, Needs Node.js

Security

What our scanner noticed· Low risk

  • Scripts that your agent may run

This skill includes scripts that your agent may run. Read them before you use it.

A static scan is not a guarantee. Skills are third-party content: review a skill before you let an agent use it.

Attribution and licence

Published by
AWS Labs
Publisher
AWS Labs (Official)
Source
awslabs/agent-plugins · plugins/sagemaker-ai/skills/hyperpod-node-debugger · commit fbefb37
Licence
Apache License 2.0 (redistribution allowed)
  • LICENSE (added by AutoGineer from LICENSE)
  • NOTICE (added by AutoGineer from NOTICE)
  • ATTRIBUTION.md (written by AutoGineer)
Synced

AutoGineer is not affiliated with or endorsed by AWS Labs or AWS Labs.

Download ZIP

The ZIP holds the skill’s files, its licence files and an ATTRIBUTION.md. Download hyperpod-node-debugger.zip